1
1
The by-pass screw
– If you change from natural gas 20 mbar to liquid gas, fully tighten the adjustment
screw in.
– If you change from liquid gas to natural gas 20 mbar, undo the by-pass screw ap
-
proximately 1/4 of a turn.
WARNING!
Make sure the flame does not go out when you quickly turn the knob from the maximum
position to the minimum position.
BURNER
NATURAL GAS
G20/20 mbar
LPG
G30/30 mbar
Injectors
Injectors
Outer ring
2x115
2x72
Inner ring
70
46
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on the rating plate agree with the
voltage and the power of the local power supply.
• This appliance is supplied with a mains cable.
• Any electrical component must be installed or replaced by the Service Force Centre tech
-
nician or qualified service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug after installation.
• Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.
• The appliance must not be connected with an extansion cable, an adapter or a multiple
connection (risk of fire). Check that the ground connection is in conformity with the
standard and regulations force.
• The power cable must be placed in such a way that it does not touch any hot part.
• Connect the appliance to the mains with a device that lets to disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm, eg. auto
-
matic line protecting cut-out, earth leakage trips or fuse.
• None of a parts of the connection cable can not get a temperature 90°C.
26
Installation