9.2 Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Triple Crown
5
7
9.3 Other technical data
TOTAL POW‐
ER:
Gas original:
LPG
30 mbar
3,8 kW /
276 g/h
Gas replace‐
ment:
G
110 (1a) 14 mbar
4,0
kW
Electric sup‐
ply:
220-240 V ~ 50/60 Hz
Appliance cat‐
egory:
II2H3B/P
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for LPG 30 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Triple Crown
3,8
1,4
98
276
9.5 Gas burners for
TOWN GAS G110 14 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Triple Crown
4,0
1,4
282
10. ENVIRONMENTAL CONCERNS
Recycle materials with the symbol .
Put the packaging in relevant containers
to recycle it. Help protect the
environment and human health by
recycling waste of electrical and
electronic appliances. Do not dispose of
appliances marked with the symbol
with the household waste. Return the
product to your local recycling facility or
contact your municipal office.
*
www.electrolux.com