15
EN
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the hood in ducting version, a rigid or
a fl exible pipe with the diameter corresponding to the
fl ange diameter is used in order to connect the hood
to the air outlet piping.
• Fix the pipe with an adequate quantity of pipe
clamps (not supplied).
• Remove possible charcoal fi lters.
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
• Insert
the
fl ange
10a
on the hood body outlet.
• Connect
the
fl ange to the outlet on the shelf over
the hood using a fl exible or rigid pipe ø120 mm.
• Fix the pipe in position using suffi cient pipe clamps
(not supplied).
• Fix the directional grille
8
on the recirculation air out-
let using the 2 screws
12e
(2,9 x 12,7) provided.
• Ensure that the activated charcoal fi lters have been
inserted.
12e
8
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm.