Safety information for the installer
•
The set-up of the electrical installation is arranged so that the appli-
ance can be isolated from the mains with a minimum 3 mm all-pole
contact separation.
Suitable separation devices include e. g. cut-outs, fuses (screw fuses
are to be taken out of the holder), RCD’s and contactors.
•
Avoid installing the appliance next to doors and under windows. Oth-
erwise hot cookware may be knocked off the rings when doors and
windows are opened.
•
The appliance must be connected to the electricity according to the
connection schematic on the outside of the terminal cover.
•
The cable which connects the appliance to the mains must corre-
spond to insulation standard H05VV-F (=227 IEC 53) as a minimum.