![AEG CCE84543CB User Manual Download Page 24](http://html.mh-extra.com/html/aeg/cce84543cb/cce84543cb_user-manual_3048449024.webp)
Problem
Possible cause
Remedy
The control bar blinks.
There is no cookware on the zone or
the zone is not fully covered.
Put cookware on the zone so that it
fully covers the cooking zone.
The cookware is unsuitable.
Use cookware suitable for induction
hobs. Refer to "Hints and tips".
The diameter of the bottom of the
cookware is too small for the zone.
Use cookware with correct dimen‐
sions. Refer to "Technical data".
The hood does not start or turns
off. The indicators above the
hood control symbols might also
blink.
The fan may turn off by itself in cer‐
tain conditions, e.g. when the room
is not properly ventilated.
Open the window. You may need to in‐
stall the window switch. Refer to "As‐
sembly". If the window switch is al‐
ready present, make sure it was cor‐
rectly installed. Refer to the installation
booklet.
Press any symbol. The hood operates
again.
The hood fan does not work
properly when the hood functions
are activated.
The ambient temperature surround‐
ing the hood is too high.
There is insufficient air circulation in‐
side and around the hood.
Deactivate the hob and unplug it from
the main power supply. Wait at least
10 seconds, then plug it in again.
Other suggestions:
Try to cool down the temperature of
the surrounding area. Take out the
hood filter and remove the residual
moisture from the inside of the hood.
Refer to "Care and cleaning". Leave
the hood system to dry for one day,
then activate the hood again.
The steam produced during
cooking is not sufficiently absor‐
bed by the hood.
The lids on the cookware are not
properly placed.
If your cookware does not have vented
lids, make sure to tilt the lids so that
the released steam is directed towards
the hood.
Refer to "Hints and Tips" for informa‐
tion on the special Steam Vented Lids
recommended to be used with the inte‐
grated hood.
The hood filter is oversaturated.
Regenerate the hood filter and reset
the notification. Refer to "Care and
cleaning".
and a number come on.
There is an error in the hob.
Deactivate the hob and activate it
again after 30 seconds. If
comes
on again, disconnect the hob from the
electrical supply. After 30 seconds,
connect the hob again. If the problem
continues, speak to an Authorised
Service Centre.
10.2 If you cannot find a solution...
If you cannot find a solution to the problem
yourself, contact your dealer or an Authorised
Service Centre. Give the data from the rating
plate. Make sure, you operated the hob
correctly. If not the servicing by a service
technician or dealer will not be free of charge,
also during the warranty period. The
information about guarantee period and
Authorised Service Centres are in the
guarantee booklet.
24 ENGLISH