AEG BSK882320M Installation Manual Download Page 2

1

5

Installation Instruction 

Warning! 

Before proceeding with installation, read 

the safety information in the User Manual.

The oven is designed to be connected to 230 - 240V  

~ (50Hz) electricity supply. 

The oven has an easily accessible terminal block which 

is marked as follows:

Letter L - Live terminal

Letter N - Neutral terminal

- Earth terminal

CAUTION!

This oven must be earthed!

The cable used to connect the oven to the electrical 

supply must comply to the specifications given below.

For UK use only

Connection 

via

Min. size 

Cable/flex

Cable/flex 

type

Fuse

Cooker 

Control 

Circuit

2,5 mm²

PVC / PVC 

twin and 

earth

min: 15 A

max: 20 A

It is necessary that you install a double pole switch 

between the oven and the electricity supply (mains),  

with a minimum gap of 3 mm between the switch con-

tacts and of a type suitable for the required load in com-

pliance with the current regulations.
The switch must not break the yellow and green earth 

cable at any point.

EN

After installation and connecting, the cable must 

be placed so that it cannot at any point reach a 

temperature of more than 50°C above the 

ambient temperature.

Before the oven is connected, check that the 

main fuse and the domestic installation can 

support the load; and that the power supply is 

properly earthed.

The manufacturer declines any responsibility

should these safety measures not be carried out.

Attention: 

The new appliance may only be installed and 

connected by a registered expert.

  Please comply with this. If you do not, any  

damage resulting is not covered by the warranty.

Safety information for the installer

• The electrical installation is to be set up so 

that the appliance can be isolated from the 

mains with a minimum 3 mm all-pole contact 

separation.

• Suitable separation devices include e.g.

cut-outs, fuses (screw fuses are to be taken

out of the holder), RCD’s and contactors.

•  Anti-shock protection must be provided by the  

installation.

• The built-in unit must meet the stability

requirements of DIN 68930.

• Built-in ovens and built-in cooking surfaces 

are  fitted  with  special  connection  systems.

For safety reasons, they must only be 

combined with appliances from the same 

manufacturer.