3.7 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
L
N
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connected
to the network phase.
3.8 Attaching the seal - On-
top installation
1. Clean the worktop around the cut out
area.
2. Attach the supplied seal stripe to the
lower edge of the hob, along the
outer edge of the glass ceramic. Do
not stretch it. Make sure that the
ends of the seal stripe are located in
the middle of one side of the hob.
3. Add some millimetres to the length
when you cut the seal stripe.
4. Join the two ends of the seal stripe
together.
3.9 Assembly
min.
450mm
min.
650mm
min.
2mm
www.aeg.com