8.4 Cleaning the drain
Periodically clean the drain hole to
prevent water from overflowing and
dripping onto the stored bottles. The
drain hole is located on the rear wall in
the lower left part of the appliance. To
reach it more easily, slightly press the
covering grid.
For this purpose, use a thin, plastic, non-
sharp stick.
1
2
3
8.5 Periods of non-operation
When the appliance is not in use for long
periods, take the following precautions:
1. Disconnect the appliance from
electricity supply.
2. Remove all items.
3. Clean the appliance and all
accessories.
4. Leave the door open to prevent
unpleasant smells.
When the appliance is not in use due to
power failure:
• Most power failures are corrected
within a few hours and don't affect the
temperature of your appliance if you
minimize the door opening.
• If the power is going to be off for a
longer time, you need to take the
proper steps described above.
9. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
9.1 What to do if...
Problem
Possible cause
Solution
The appliance does not op‐
erate.
The appliance is switched
off.
Switch on the appliance.
The mains plug is not con‐
nected to the mains socket
correctly.
Connect the mains plug to the
mains socket correctly.
There is no voltage in the
mains socket.
Connect a different electrical
appliance to the mains socket,
to check if electricity is flowing.
If not, contact a qualified elec‐
trician.
The circuit breaker tripped
or a blown fuse.
Turn on the circuit breaker or
change the fuse.
The compressor operates
continually.
Temperature is set incor‐
rectly.
Refer to the "Operation" chap‐
ter.
The room temperature is
too high.
Refer to the "Installation"
chapter.
ENGLISH
67