26
www.aeg.com
3. When the container is full of water,
put the drainage duct back again and
empty the container. Do step 2, 3
again and again until no more water
flows out from the drain pump.
5. Remove fluff and objects from the
pump (if there are any).
6. Make sure that the impeller of the
pump can turn. If this does not occur,
contact the service centre.
7. Clean the filter under the water tap.
4. Push back the drainage duct and
turn the filter counter-clockwise to
remove it.