---------------------------------------------------------------27/51---------------------------------------
After the erase operation has finished the device will return to the standard
operating mode.
6.9
Reading time
This sets the time frame for one reading attempt. The time could be changed
with the arrow buttons in 0,5s steps. A new time is set by pressing the main
button.
Reading Time
2.0 s
Default value
4 s
min. value
0,5 s
max. value
12,5 s
This setting is stored in the device and is still valid after power off/on operation.
For optimal reading performance this setting is recommended to be between 2-4
seconds.
6.10
Turn-off time
Sets the time until the ARE H9 HF will automatically shut off while no button is
pressed or activity lasts. It could be change with the arrow buttons in 5s steps.
Turn-Off Time
20 s
A new time is set by pressing the main button.
Default value
20 s
min. value
10 s
max. value
300 s
This setting is stored in the device and is still valid after power off/on operation.