--------------------------------------------------------------------------------4/20--------------------------------------------------------------------------------
1
Introduction
This document will describe the components of the AMP 4/8 and the procedure how to do the first
set up of the reader.
The main features of the reader are listed below:
up to 8 antennas connectable
integrated RS232 or USB interface
3 different types of controlling possible (RS232/USB, with the reader ARE i2, with digital in-
puts)
power supply from 9V DC to 30V DC (see chapter 2.3)
compact housing
the protection class of the housing is IP65
2
Installation
To ensure a proper function of the AMP 4/8 you have to follow the steps in following chapters. The
installation should be done by trained people.
2.1
Mounting of the housing
The AMP 4/8 can be mounted to any other mechanic construction. It is recommended to protect the
housing against heavy mechanical interactions and drippy fluids.
With the help of the plastic bars, the reader can be mounted or screwed on to the most fastening
elements without open the housing of the device.
2.2
Grounding of the AMP 4/8
The AMP 4/8 should be grounded. The connector is placed at the side of the housing (6.35 mm flat
contact).
To avoid EMV-problems, the cable to ground ought to be very short with low impedance.