background image

9

English

 

WARNING: 

 

If any parts are damaged or missing do not operate 

this product until the parts are replaced. Failure to 

heed  this  warning  could  result  in  serious  personal 

injury.

 

WARNING: 

 

Do  not  attempt  to  modify  this  tool  or  create 

accessories  not  recommended  for  use  with  this 

tool.  Any  such  alteration  or  modification  is  misuse 

and could result in a hazardous condition leading to 

possible serious personal injury.

OpERATION

  DANGER:

 

Carbon monoxide.

 Using a generator indoors WILL 

KILL YOU IN MINUTES.

Generator exhaust contains high levels of carbon monoxide 

(CO), a poisonous gas you cannot see or smell. If you can 

smell the generator exhaust, you are breathing CO. But even 

if you cannot smell the exhaust, you could be breathing CO.

n

 

Never  use  a  generator  inside  homes,  garages, 

crawlspaces,  or  other  partly  enclosed  areas.  Deadly 

levels of carbon monoxide can build up in these areas. 

Using  a  fan  or  opening  windows  and  doors  does  NOT 

supply enough fresh air.

n

 

ONLY use a generator outdoors and far away from open 

windows, doors, and vents. These openings can pull in 

generator exhaust.

Even when you use a generator correctly, CO may leak into 

the home. ALWAYS use a battery-powered or battery-backup 

CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has 

been running, move to fresh air RIGHT AWAY. See a doctor. 

You could have carbon monoxide poisoning.

  DANGER: 

 

Failure  to  properly  ground  generator  can  result  in 

electrocution, especially if the generator is equipped 

with  a  wheel  kit.  Generators  have  to  be  properly 

grounded  to  an  approved  earth  ground.  Call  an 

electrician for local grounding requirements. 

  WARNING: 

 

Do  not  allow  familiarity  with  tools  to  make  you 

careless.  Remember  that  a  careless  fraction  of  a 

second is sufficient to inflict serious injury.

  WARNING:

 

Do  not  use  any  attachments  or  accessories  not 

recommended by the manufacturer of this product. 

The  use  of  attachments  or  accessories  not 

recommended can result in serious personal injury.

AppLICATIONs

This  generator  is  designed  to  supply  electrical  power  for 

operating  compatible  electrical  lighting,  appliances,  tools, 

and motor loads.

BEfORE OpERATING THE UNIT

Position the generator on a flat surface before checking fluid 

levels or adding fluid.

  CAUTION:

 

Attempting  to  start  the  engine  before  it  has  been 

properly filled with oil will result in equipment failure.

CHECKING/ADDING OIL

See Figure 4.

Engine oil has a major influence on engine performance and 

service life. For general, all-temperature use, SAE 10W-40 is 

recommended. Always use a 4-stroke motor oil that meets or 

exceeds the requirements for API service classification SJ.

NOTE:

  Non-detergent  or  2-stroke  engine  oils  will  damage 

the engine and should not be used. 

n

  Unscrew the oil cap/dipstick and remove.

n

  Wipe dipstick clean and re-seat in hole; do not re-thread.

n

  Remove  dipstick  again  and  check  oil  level.  Oil  level 

should fall within the level indicator area on the dipstick.

n

  If  level  is  low,  add  engine  oil  until  the  fluid  level  rises 

to  the  upper  portion  of  the  level  indicator  area  on  the 

dipstick. 

n

  Replace and secure the oil cap/dipstick.

CHECKING/ADDING fUEL 

See Figure 5.

n

  Check  the  fuel  level  gauge.  If  fuel  is  needed,  continue 

with the next step. 

n

  Remove the fuel cap.

n

  Fill the fuel tank to 25mm below the top of the fuel neck.

n

  Replace and secure the fuel cap.

NOTE:

  Always  use  unleaded  gasoline  with  a  pump  octane 

rating of 86 or higher. Never use old, stale, or contaminated 

unleaded fuel, and do not use an oil/gas mixture. Do not allow 

dirt or water into the fuel tank.

Summary of Contents for AGN6000DB

Page 1: ...Original Instructions AGN6000DB PORTABLE GENERATOR SET ...

Page 2: ... bolt recoil starter grip air filter choke lever fuel valve FUEL CAP FUEL tank Fuel level gauge Fuel level gauge Circuit Breaker ENGINE SWITCH fuel tank fuel cap oil cap dipstick oil fill hole carburetor drain screw oil cap dipstick Fig 2 Fuel level gauge ...

Page 3: ...Fig 6 ON OFF ON OFF Fig 8 Fig 7 recoil startER grip fuel valve CHOKE LEVER TO START choke closed TO run choke open LATCHES air filter cover filter elementS air filter unit Fig 9 ...

Page 4: ...21 2 Fig 10 ON OFF Fig 11 Fig 12 Fig 13 ON OFF ON OFF spark plug cap spark plug fuel line fuel valve BARB fuel valve o ring filter sediment cup oil cap dipstick ...

Page 5: ...hen you are tired or under the influence of drugs alcohol or medication n Keep all parts of your body away from any moving parts and all hot surfaces of the unit n Product users in some states must comply with fire prevention regulations This product is not equipped with a spark arrestor Check with the federal areas or local authorities in your area before use n Do not touch bare wire or receptacl...

Page 6: ...an someone this tool loan them these instructions also SPECIFIC SAFETY RULES WARNING When this generator is used to supply a building wiring system the generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70 National Electrical Code The generator shall be connected through a transfer switch that switches al...

Page 7: ... face shield when operating this product Safety Alert Precautions that involve your safety Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Toxic Fumes Running the generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death Fire Explosion Fuel and its vapors are extremely...

Page 8: ...arest AUTHORISED SERVICE CENTRE for repair When servicing use only identical replacement parts WARNING Observe all normal safety precautions related to avoid electrical shock DANGER To avoid death or serious personal injury do not attempt to operate this product until you read thoroughly and understand completely the operator s manual If you do not understand the warnings and instructions in the o...

Page 9: ...The unit is equipped with an oil sensor which will automatically shut off the engine if oil level falls below a safe limit Hot SURFACE warning Do not touch the muffler or aluminum cylinder of the engine They are very HOT and will cause severe burns Don t put any flammable or combustible materials in the direct path of the exhaust ICON WARNING READ THE OWNERS MANUAL AND ALL LABELS BEFORE OPERATING ...

Page 10: ...t the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilise engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilise 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Ta...

Page 11: ...88 Engine Type 4 Stroke air cooled OHV Unleaded fuel Bore x Stroke 88x64 Displacement cc 389 Starting System DC Start Fuel Type Unleaded fuel Lubrication oil SAE 10W 30 Engine Oil Volume L 1 1 Fuel Tank Capacity l 25 Max Output hp 13 0 Max Output rpm 3 600 Full Load h 10 Half Load h 18 0 CE Yes Euro Emission Yes 4m Noise Level LpA dB A 76 4m Noise Level LwA dB A 96 Uncertainty dB A 2 7m Noise Leve...

Page 12: ...tor has the following single phase 50 Hz outlets one 230 Volt AC 16 Amp receptacle These can be used for operating appropriate appliances electrical lighting tools and motor loads recoil starter grip The recoil starter grip is used along with the engine switch to start the generator s engine DC TERMINALS The DC terminals may ONLY be used for charging 12 volt automotive type batteries The terminals...

Page 13: ...ith tools to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating compatib...

Page 14: ...d in a vehicle disconnect the vehicle ground battery cable from the battery negative terminal n Connect the positive battery cable to the battery positive terminal n Connect the other end of the positive battery cable to the generator positive terminal n Connect the negative battery cable to the battery negative terminal n Connect the other end of the negative battery cable to the generator negati...

Page 15: ...over and set aside n Remove the filter elements n If the filter elements are dirty clean with warm soapy water Rinse and let dry n Apply a light coat of engine oil to the elements then squeeze it out n Replace the elements in the air filter unit n Replace the air filter cover and close latches to secure NOTE Do not run the generator without the air filter Rapid engine wear will result changing eng...

Page 16: ...fore storage may help prevent gum deposits in the fuel system DRAINING THE FUEL TANK See Figure 13 n Turn the engine switch off O n Close fuel valve n Remove the fuel line from the barb by squeezing the ends of the retaining clip and sliding the fuel line off n Install one end of a drain line over the barb and place the other end in a fuel container large enough to catch the fuel being drained fro...

Page 17: ...ife Forrecommendations contactyournearestauthorizedservicecenter MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Every 6 months or 100 hours of operation Every year or after 300 hours of operation Check Engine Oil n Change Engine Oil n n Check Air Filter n Clean Air Filter n Change Air Filter n Clean Carburetor Sediment Cup n Ch...

Page 18: ...cuit breaker is off Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavyloadisnotacause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different brand...

Page 19: ...15 English WIRING DIAGRAM AGN6000DB ...

Page 20: ...zed reseller or if product is sold AS IS and or WITH ALL FAULTS Where permitted the provisions of this limited warranty are in lieu of any other written warranty whether express or implied written or oral including any warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL WE BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OUR MAXIMUM LIABILITY SHALL...

Page 21: ...34 0 91 627 93 29 TECHTRONIC INDUSTRIES ASIA CO LTD 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong Kong Tel 852 2402 6888 RYOBI TECHNOLOGIES GMBH Itterpark 4 D 40724 Hilden DEUTSCHLAND Tel 49 0 2103 2958 0 Fax 49 0 2103 2958 29 RYOBI TECHNOLOGIES GMBH Vertriebsbüro Österreich Schinitzgasse 13 A 8605 Kapfenberg Tel 43 0 3862 23590 0 Fax 43 0 3862 23590 25 TECHTRONIC INDUSTRIES AUSTRALIA PTY ...