AEG AC1030S Original Instructions Manual Download Page 7

7

7

AIR COMPRESSOR USE AND CARE

 

Do not exceed the pressure rating of any component in the 

system.

 

Protect material lines and air lines from damage or puncture. 

Keep hose and power cord away from sharp objects, chemical 

spills, oil, solvents, and wet floors.

 

Check hoses for weak or worn condition before each use, making 

certain all connections are secure. Do not use if defect is found. 

Purchase a new hose or notify an authorised service centre for 

examination or repair.

 

Release all pressures within the system slowly. Dust and debris 

may be harmful.

 

Store idle air compressors out of the reach of children and other 

untrained persons. Air compressors are dangerous in the hands 

of untrained users.

 

Maintain air compressors with care. Follow maintenance 

instructions. Properly maintained products are easier to control.

 

Check for misalignment or binding of moving parts, breakage 

of parts, and any other condition that may affect the product’s 

operation. If damaged, have the air compressor serviced before 

using. Many accidents are caused by poorly maintained products.

 

Keep the exterior of the air compressor dry, clean, and free from 

oil and grease. Always use a clean cloth when cleaning. Never use 

brake fluids, gasoline, petroleum-based products, or any strong 

solvents to clean the unit. Following this rule will reduce the risk 

of deterioration of the enclosure plastic.

SERVICE

 

When servicing use only identical replacement parts. Use of any 

other parts may create a hazard or cause product damage.

Save these instructions. Refer to them frequently and use them 

to instruct other users. If you loan someone this tool, loan them 

these instructions also.

AIR COMPRESSOR SAFETY WARNINGS

 

Know your air compressor. Read operator’s manual carefully. 

Learn its applications and limitations, as well as the specific 

potential hazards related to this product. Following this rule will 

reduce the risk of electric shock, fire, or serious injury.

 

Drain tank of moisture after each day’s use. If unit will not be used 

for a while, it is best to leave drain valve open until such time as it 

is to be used. This will allow moisture to completely drain out and 

help prevent corrosion on the inside of tank.

 

Risk of fire or explosion. Do not spray flammable liquid in a 

confined area. Spray area must be well ventilated. Do not smoke 

while spraying or spray where spark or flame is present. Keep 

compressors as far from the spraying area as possible, at least 

10 m (33 feet) from the spraying area and all explosive vapours.

 

Risk of bursting. Do not adjust regulator to result in output 

pressure greater than marked maximum pressure of attachment. 

Do not use at pressure greater than 10 bar (145 psi).

 

To reduce the risk of electric shock, do not expose to rain. Store 

indoors.

 

Inspect tank yearly for rust, pin holes, or other imperfections that 

could cause it to become unsafe.

 

Never weld or drill holes in the air tank.

 

Never use the air compressor with the guard removed.

 

Make sure the hose is free of obstructions or snags. Entangled 

or snarled hoses can cause loss of balance or footing and may 

become damaged.

 

Use the air compressor only for its intended use. Do not alter or 

modify the unit from the original design or function.

 

Always be aware that misuse and improper handling of this 

product can cause injury to yourself and others.

 

Never leave a tool unattended with the air hose attached.

 

Never point any air tool toward yourself or others.

 

Do not operate this air compressor if it does not contain a legible 

warning label.

 

Do not continue to use a tool or hose that leaks air or does not 

function properly.

 

Always disconnect the air supply and power supply before making 

adjustments, servicing a product, or when a product is not in use.

 

Do not attempt to pull or carry the air compressor by the hose.

 

Your tool may require more air consumption than this air 

compressor is capable of providing.

 

Always follow all safety rules recommended by the manufacturer 

of your air tool, in addition to all safety rules for the air compressor. 

Following this rule will reduce the risk of serious personal injury.

 

Never direct a jet of compressed air toward people or animals. 

Take care not to blow dust and dirt towards yourself or others. 

Following this rule will reduce the risk of serious injury.

 

Do not use this air compressor to spray chemicals. Your lungs 

can be damaged by inhaling toxic fumes. A respirator may be 

necessary in dusty environments or when spraying paint. Do not 

carry while painting.

 

Inspect product cords and hoses periodically and, if damaged, 

have them repaired at your nearest authorised service centre. 

Constantly stay aware of cord location. Following this rule will 

reduce the risk of electric shock or fire.

 

Never use an electrical adaptor with this grounded plug.

 

Check for damaged parts. Before further use of the air compressor 

or air tool, a guard or other part that is damaged should be 

carefully checked to determine that it will operate properly and 

perform its intended function. Check for alignment of moving 

parts, binding of moving parts, breakage of parts, mounting, 

and any other conditions that may affect its operation. A guard 

or other part that is damaged should be properly repaired or 

replaced by an authorised service centre. Following this rule will 

reduce the risk of serious injury.

 

Never store a tool with an air line connected. Storing the tool while 

connected to an air supply can result in unexpected operation, 

firing or movement and possible serious personal injury.

 

Protect your lungs. Wear a face or dust mask if the operation is 

dusty. Following this rule will reduce the risk of serious personal 

injury.

 

If the power supply cord is damaged, it must be replaced only by 

the manufacturer or by an authorised service centre to avoid risk.

 

Save these instructions. Refer to them frequently and use them 

to instruct others who may use this product. If you loan someone 

this product, loan them these instructions also.

 

The machine shall be connected to a circuit protection device 

(fuse or circuit breaker).

 

Connect the mains lead to a standard electrical supply which has  

protection devices of over current (10A, 220-240V, 50Hz).

 

Operate the machine from the front of the control panel.

 

When the machine is in operation, many parts of machine may 

cause a high temperature. Use necessary personal protection 

equipment such as gloves to avoid injuries resulting from a high 

temperature.

 

When using the product with an extension cord, use a 3 x 1.5mm

2

 

heavy duty extension cord only.

 

This machine is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised 

to ensure that they do not play with the machine.

Summary of Contents for AC1030S

Page 1: ...AC1030S Original instructions ...

Page 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Page 3: ...3 5 1 2 6 1 Air filter assembly 1 Front handle 2 Handle slot 3 Bolt 1 Rubber foot 2 M8 flat washer 3 M8 bolt 4 M8 hex nut 1 Air filter assembly x2 2 Pressure relief valve 3 Power cord 4 Front handle 5 AUTO OFF switch 6 Pressure regulator knob 7 Regulator pressure gauge 8 Tank pressure gauge 9 Quick connect coupler 10 Tank 11 Rubber foot x2 12 Wheel x2 13 Rear handle 14 Drain valve ...

Page 4: ...oupler 2 Quick connect air fitting 3 To close counterclockwise 4 Pressure relief valve 5 Regulator locking ring 1 Quick connect air fitting 2 Quick coupler 1 AUTO position 2 OFF position 3 Tank pressuse gauge 4 Regulated pressure gauge 5 To open clockwise 6 Regulator locking ring 2 ...

Page 5: ... 3 2 1 2 3 Fig 12 Fig 10 Fig 11 1 1 Pressure relief valve 2 To close 3 To release air 1 Air filter housing 2 Air filter 3 Air filter cover 4 Air hose 1 Drain valve 2 Open position 3 Closed position 2 3 4 1 ...

Page 6: ... it is in operation Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension cord while operating Never use in an explosive atmosphere Normal sparking of the motor c...

Page 7: ...l unattended with the air hose attached Never point any air tool toward yourself or others Do not operate this air compressor if it does not contain a legible warning label Do not continue to use a tool or hose that leaks air or does not function properly Always disconnect the air supply and power supply before making adjustments servicing a product or when a product is not in use Do not attempt t...

Page 8: ... on this list are not assembled to the product by the manufacturer and require customer installation Use of a product that may have been improperly assembled could result in serious personal injury Inspect the product carefully to make sure no breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the product W...

Page 9: ...CTING AIR HOSE See figure 7 NOTE For operation using pressures above 7 bar 102 psi delivery hoses should be fitted with a safety cord e g wire rope 1 Make sure the air compressor is off and unplugged 2 Rotate pressure regulator knob fully counterclockwise 3 Rotate regulator locking ring fully counterclockwise 4 Confirm that the outlet pressure is at zero 0 bar 5 Attach hose with quick connect air ...

Page 10: ...lockwise and the air should stop escaping Keep the pressure relief valve clean and do not cover it with any object WARNING If air leaks after the pressure relief valve has been closed or if the valve is stuck and cannot be actuated do not use the air compressor until the pressure relief valve has been replaced Use of the air compressor in this condition could result in serious personal injury DRAI...

Page 11: ...eed to be replaced which have not been described please contact one of our AEG service agents see our list of guarantee service addresses If needed an exploded view of the product can be ordered Please state the Article No as well as the machine type printed on the label and order the drawing at your local service agents or directly at Techtronic Industries Australia Pty Ltd PO Box 1065 Mount Wave...

Page 12: ...ned off at the mains before the onboard switch Turn off the onboard switch which releases line pressure and turn on from the onboard switch Current limiting protector cuts out repeatedly Low voltage Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire and cord lengt...

Page 13: ...PROBLEM POSSIBLE CAUSE SOLUTION Air output lower than normal Broken inlet valves Take compressor to service centre Connections leaking Tighten connections Hose or tool leaking Check replace leaking hose tool ...

Page 14: ...13 14 15 19 20 23 24 25 26 27 28 31 32 33 34 5 2 36 37 38 39 40 42 41 22 29 17 18 16 56 57 58 59 53 63 62 64 65 66 52 50 49 47 77 76 75 78 51 79 60 61 68 71 69 72 73 74 45 46 48 55 43 44 67 70 30 35 54 82 83 86 85 84 81 80 PARTS LIST ...

Page 15: ...er 32 Bearing 6908 54 Connector 76 Nut 11 Cylinder obturating ring 33 Bolt M8 10 55 Pressure gauge 77 Bolt M8 12 Cylinder cover obturating ring 34 Snap ring 56 High pressure pipe 78 Handle 13 Cylinder head 35 Right crankcase 57 Check valve 79 Handle cover 14 Hexagon socket head screw M6 70 36 Bolt M5 192 58 Unloading pipe 80 Spring washer 15 Spring washer 37 Spring washer 59 Protection ring 81 Was...

Page 16: ...htronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand www aegpowertools com au www aegpowertools co nz AEG is a registered trade mark used under license from AB Electrolux publ NITTO is a registered trade mark owned by Nitto Kohki Co Ltd 20210802v1 ...

Reviews: