INSTALLATION
POSITIONING
WARNING!
If you are discarding an old appli-
ance that has a lock or catch on
the lid, you must ensure that it is
made unusable to prevent young
children being trapped inside.
The appliance shall have the plug
accessible after installation.
This appliance can be installed in a dry,
well ventilated indoor (garage or cellar),
but for optimum performance install this
appliance at a location where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Cli-
mate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
ELECTRICAL CONNECTION
Before plugging in, ensure that the volt-
age and frequency shown on the rating
plate correspond to your domestic power
supply.
The appliance must be earthed. The pow-
er supply cable plug is provided with a
contact for this purpose. If the domestic
power supply socket is not earthed, con-
nect the appliance to a separate earth in
compliance with current regulations, con-
sulting a qualified electrician.
The manufacturer declines all responsibili-
ty if the above safety precautions are not
observed.
This appliance complies with the E.E.C.
Directives.
VENTILATION
REQUIREMENTS
1.
Put the freezer in horizontal position
on a firm surface. The cabinet must
be on all four feet.
2.
Make sure that the clearance be-
tween the appliance and rear wall is 5
cm.
3.
Make sure that the clearance be-
tween the appliance and the sides is 5
cm.
The airflow behind the appliance must be
sufficient.