69
1
Safety Instructions for the Installer
•
A device must be provided in the electrical installation which allows
the appliance to be disconnected from the mains at all poles with a
contact opening width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses
(screw type fuses are to be removed from the holder), earth leakage
trips and contactors.
•
In respect of fire protection, this appliance corresponds to
EN 60 335-2-6. This type of appliance may be installed with a high
cupboard or wall on one side.
•
Drawers may not be fitted underneath the hob.
•
The installation must guarantee shock protection.
•
The kitchen unit in which the appliance is fitted must satisfy the sta-
bility requirements of DIN 68930.
•
For protection against moisture, all cut surfaces are to be sealed with
a suitable sealant.
•
On tiled work surfaces, the joints in the area where the hob sits must
be completely filled with grout.
•
On natural, artificial stone, or ceramic tops, the snap action springs
must be bonded in place with a suitable artificial resin or mixed ad-
hesive.
•
Ensure that the seal is correctly seated against the work surface with-
out any gaps. Additional silicon sealant must not be applied; this
would make removal more difficult when servicing.
•
The hob must be pressed out from below when removed.