8
C – Electrical requirements
WARNING:
All aspects of the installation must conform with the requirements of the Standard North
America (within North America) wiring rules, as well as your local electrical and building
codes and regulations, and any other applicable requirements and conditions of your local
power supply authority.
A licensed electrician must perform the electrical work when installing this appliance. The
supply cable and fuse rating must be suitable for the appliance
WARNING:
To avoid power borne interference, this appliance must be installed individually on a separate and
distinct final sub-circuit.
Voltage supply connection
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid hazard
When connected to a sub circuit, protected by a circuit breaker, it is recommended the circuit
breaker be the same as the total rating of the appliance.
To full disconnect the power supply, it is necessary to have a proper mean in the fixed
wiring in accordance with the wiring rules. It must have full disconnection under
overvoltage category III conditions.
The range is supplied with a power cord and plug, which can be withdrawn from the wall
socket
Electrical Loads
Oven
2350 W
Oven
2350 W
Grill
2800 W
Grill
2800 W
Oven fan and light
90 W
Oven fan and
light
90 W
Cearmic cooktop
6400 W
Gas cooktop
TOTAL RATING AT 208V
8.70 KW
TOTAL RATING
AT 208V
3.22KW
TOTAL RATING AT 240V
11.45 KW
TOTAL RATING
AT 240V
4.05KW