• It is advisable to apply for authorization from the relevant controlling

authority when connecting the outlet to an unused chimney flue or
combustion gas duct.
The air outlet installation must comply with the regulations laid down
by the relevant authorities.

• When the unit is used in its extractor version, a sufficiently large

ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.

• National and regional building regulations impose a number of

restrictions on using hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-heaters and gas fires, in the
same room.

• Hoods can only be used safely with appliances connected to a

chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approxi-
mately 500-600 cm

 large to avoid the possibility of a depression

being created during operation of the hood.

• If you have any doubts, contact the relevant controlling authority or

building inspector’s office.

• Since the rule for rooms with fuel burning appliances is “outlet hole

of the same size as the ventilation hole”, a hole of 500-600 cm

2

,

which is to say a larger hole, could reduce the performance of the
extractor hood.

• If the hood is used in its filtering function, it will operate simply and

safely in the above conditions without the need for any of the
aforementioned measures.

• When the hood is used in its extractor function, the following rules

must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
    always follow a gentle curve only
— keep the hose as large as possible (preferably the same
diameter as the outlet hole).

• Failure to observe these basic instructions will drastically reduce the

performance and increase the noise levels of the extractor hood.

Summary of Contents for DM8600

Page 1: ...600 Dunstabzugshaube Hotte aspirante Cappa aspirante Cooker hood Montage undGebrauchsanweisung Notice d utilisation et d installation Istruzioni di montaggio e uso Operating and Installation Instructi...

Page 2: ...50 Printed on recycled paper AEG putting words into action...

Page 3: ...coal filter LED E 57 Resetting the saturation indicator 57 Maintenance and care 58 Metal grease filter 58 Open the metal grease filter 58 Charcoal filter 59 Changing the light bulb 60 Cleaning 60 Spec...

Page 4: ...e hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up resulting in a fire hazard for the installer When used as an extractor unit the hood...

Page 5: ...ge to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule f...

Page 6: ...see Special Accessories The air is discharged to the outside through a pipe which must be fitted to connection flange D Fig 1 In order to obtain the best performance the hose should have a diameter e...

Page 7: ...You will need an original AEG charcoal filter for the filtering function See Special Accessories Fix the deflector using 4 screws 2 9x6 5 mm Fig 2 Optionally the position of the chimney elements can b...

Page 8: ...ndicates speed 1 LED D Indicates speed 2 and saturation of the grease filter LED E Indicates speed 3 and saturation of the charcoal filter LED flashing LED F Indicates Intensive speed LED G Intensive...

Page 9: ...r will be enabled To disable it Press buttons B and G again simultaneously and hold them for 3 seconds until the charcoal filter LED goes out Grease filter LED D LED D will start to flash when it is t...

Page 10: ...en extract the filter pulling downwards Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the proce...

Page 11: ...e filter and later causes bad odours To reactivate the charcoal the filter should be dried in an oven for 10 minutes with a temperature of maximum 100 C After approximately three years of use the char...

Page 12: ...e of the same type Remount the lamp cover If the light does not come on make sure the bulb has been inserted in correctly before contacting the technical assistance service Cleaning Warning always dis...

Page 13: ...whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code number 2 The serial number E Nr 3 The manufacturing number F Nr This informa...

Page 14: ...orbed power 210 W Motor absorption 1 x 170 W Lighting 2 x 20W Lenght of the cable 150 cm Mounting accessories included 1 deflector 1 chimney support 1 reduction flange 125 120 mm 1 support bracket 5 w...

Page 15: ...tance of at least 3 mm between contacts must be provided This disconnector may be for example a switch fuses plug fuses must be removed from the fuse box fault current switches and remote switches wit...

Page 16: ...ood 4 adjust its position 5 6 and from the inside of the hood sign one point for definitive fixing 7 remove the hood and drill an hole 8mm 8 fit a wall plugs hang the hood again and fix it definitivel...

Page 17: ...65 Fig 6 Fig 6 1...

Page 18: ...de vapeur Accessori speciali Mantelli Special accessories Vapour screen SM 8090 A 90cm E Nr 942 120 654 SM 8060 A 60cm E Nr 942 120 700 SM 8091 E Nr 942 120 655 SM 8092 A 90cm E Nr 942 120 656 SM 8062...

Page 19: ...67...

Page 20: ...ld s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators co...

Reviews: