55
Electrical connection (not for UK)
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to any
standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must
only be installed by an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector with a distance of at
least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be carried out by an
authorised electrician.
Electrical connection for UK only
WARNING: DOUBLE INSULATED DO NOT EARTH
Electrical Requirements
Any permanent electrical installation must comply with the latest I.E.E.
Regulations and local Electricity Board regulations. For your own safety
this should be undertaken by a qualified electrician e.g. your local
Electricity Board, or a contractor who is on the roll of the National
Inspection Council for Electrical Installation Contracting (NICEIC) or a
suitably competent person.
Electrical Connection
Before connecting to the mains supply ensure that the mains voltage
corresponds to the voltage on the rating plate inside the cooker hood.
This appliance is fitted with a 3 core mains cable and must be perma-
nently connected to the electricity supply via a double-pole switch
having 3mm minimum contact gap on each pole. A Switched Fuse
Connection Unit to BS1363 Part 4, fitted with a 5 Amp time delay fuse,
is a recommended mains supply connection accessory to ensure
compliance with the Safety Requirements applicable to fixed wiring
instructions.
This appliance conforms to BS 800: 1988 and EEC
Directive No. 78 308 regarding suppression of radio and television
interference.
Safety warnings for the electrician
The following is valid in Ireland only:
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N,
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L.