background image

R-DAS Tiny user’s manual V1.4 

©2007 AED Electronics

 

 
Optionally, the user can supply an external igniter supply as shown in Fig. 3. 

 

1. VCC - Purple

2. GND - Blue

3. Vcap - Green

4. Vign - Yellow

5. Drogue - Orange

6. Main - Red

7. Igniter 3 - Brown

8. Igniter 4 - Black

R-DAS Board

User supplied

Battery for power supply

Firing capacitor

Pyro outputs

Igniter supply

Safe/Arm switch

Drogue igniter

Main igniter

10k-Ohm dummy

Breakwire

External igniter supply

 
Figure 3: 

R-DAS Tiny wiring with optional igniter power supply, breakwire, and un-used Pyro 3 output. 

 

Note:

 Earlier versions of the wiring loom had a white #1 wire color. 

 
LED’s 

 

There are four red LED’s on the R-DAS board. These LED’s are used to indicate continuity of the igniters. 
When a breakwire is selected the LED for igniter #4 will flash once every second to indicate that this pin is 
configured as a breakwire input. When the breakwire is triggered the LED will be on for one second. After this it 
will remain off. 
 

X-acceleration 

 

The R-DAS is factory configured for dual axis acceleration measurement. The acceleration in the Z-axis is 
always enabled and cannot be switched of by the user. The acceleration in X-direction is connected to ADC5 by 
means of a solder jumper. If storage of the X-acceleration is desired, ADC5 should be selected in the sampling 
section of the R-DAS configuration menu. If ADC5 is to be used as a regular analog input, the solder jumper 
should be set to E (external) instead of A (acceleration). 
 