ITALO 2_IM_ENG - Rev.03 of 27/10/14
Page 1 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
0°
10°
ATTACHMENT
Pic. 2
M8 split washer and plain washer
Set screw wrench: 6mm
Twisting moment: 10Nm
20°
5°
15°
M8
/ 5/16"
Set
screws
Set screw wrench: 4mm
Twisting moment: 8Nm
--------------------------------
M8
/ 5/16"
nuts
Adjustable wrench: 13mm
Twisting moment: 8Nm
Pic. 4
Pic. 5A – Post-top mounting
Pic. 5B –
Arm
mounting
Pic. 3A – Post-top mounting
Pic. 3B – Bracket mounting
Sign reference
0°
-10°
-20°
-5°
Sign reference
-15°
Pic. 1
MOUNTING AND MAINTENANCE INSTRUCTION
Post-top or bracket mounting
ITALO 2 is equipped with an universal attachment (post-top or bracket mounting)
according to the ordered version:
- Attachment Ø33-60mm.
Ø1-3/8" - 2-3/8"
- Attachment Ø60-76mm.
Ø2-3/8" - 3"
Place correctly the attachment as indicated in Pic. 5A (Post-top) or in Pic. 5B
(Bracket).
Fix the attachment to the luminaire with the two M8 screws as indicated in Pic. 2.
Possible to tilt:
-
Post-top mounting:
0°, +5°, +10°, +15°, +20°
-
Bracket mounting:
0°, -5°, -10°, -15°, -20°
Use the proper sign as indicated in Pic. 3A and 3B.
The regulation of the luminaire can be done loosing the two screws (Pic. 2).
Fix the attachment to the post-top or to the bracket as indicated in Pic. 4.
To avoid any possible unscrewing of
set
screws, two M8
(5/16")
nuts have
to be tightened on the
set
screws as indicate in Pic. 4.