background image

ITALO 2_IM_ENG  - Rev.03 of 27/10/14 

Page 1 of 4

MOUNTING AND MAINTENANCE 

INSTRUCTION

10°

ATTACHMENT

 

Pic. 2

 

M8  split washer and plain washer 
Set screw wrench:   6mm 
Twisting moment:   10Nm 

20°

15°

M8

 / 5/16" 

 

Set

 screws 

Set screw wrench:  4mm 
Twisting moment:  8Nm 
-------------------------------- 

     

M8 

/ 5/16" 

nuts 

Adjustable wrench: 13mm 
Twisting moment:  8Nm 

Pic. 4

 

Pic. 5A – Post-top mounting 

Pic. 5B – 

Arm

 mounting 

Pic. 3A – Post-top mounting 

Pic. 3B – Bracket mounting 

Sign reference 

-10°

-20°

-5°

 

Sign reference 

-15°

Pic. 1

 

MOUNTING AND MAINTENANCE INSTRUCTION 

Post-top or bracket mounting 

ITALO 2 is equipped with an universal attachment (post-top or bracket mounting) 
according to the ordered version:  

- Attachment Ø33-60mm.

 Ø1-3/8" - 2-3/8"

 

- Attachment Ø60-76mm.

 Ø2-3/8" - 3"

Place correctly the attachment as indicated in Pic. 5A (Post-top) or in Pic. 5B 
(Bracket). 
Fix the attachment to the luminaire with the two M8 screws as indicated in Pic. 2. 
Possible to tilt: 

Post-top mounting: 

0°, +5°, +10°, +15°, +20° 

Bracket mounting: 

0°, -5°, -10°, -15°, -20° 

Use the proper sign as indicated in Pic. 3A and 3B. 

The regulation of the luminaire can be done loosing the two screws (Pic. 2). 

Fix the attachment to the post-top or to the bracket as indicated in Pic. 4. 

To avoid any possible unscrewing of 

set

 screws, two M8

  (5/16")

 nuts have 

to be tightened on the 

set 

screws as indicate in Pic. 4. 