rev. 07/07/2021
Pag. 2 of 15
Mounting Instructions
Techinical Division
BASE BA/1 & BASE BA/2
Made in Italy
PIASTRA - PLATE
i
LxL
Ø Foro Hole Ø
Spessore
Thickness
180
250x250
22
15
260
350x350
30
20
KIT TIRAFONDI
– ANCHOR BOLTS
L
500
700
Ø
M 18
M 27
Page 1: ...ggio delle basette BASE BA 1 e BASE BA 2 valide per la seguente lista di pali The following instructions show the mounting of the cover base BASE BA 1 e BASE BA 2 These instructions are valid for the...
Page 2: ...of 15 Mounting Instructions Techinical Division BASE BA 1 BASE BA 2 Made in Italy PIASTRA PLATE i LxL Foro Hole Spessore Thickness 180 250x250 22 15 260 350x350 30 20 KIT TIRAFONDI ANCHOR BOLTS i LxL...
Page 3: ...GGIO Base BA 1 per pali interrati 7 MOUNTING BA 1 Base Cover for in ground poles 7 MONTAGGIO Base BA 2 per pali con piastra 250mm x 250mm 9 MOUNTING BA 2 Base Cover for poles with 250mm x 250mm plate...
Page 4: ...ativa piastra saldata ed inserire i dadi sui tirafondi sopra la piastra Insert the pole with its welded plate and insert the bolts over the plate on the anchor bolts 4 Sistemare il palo con piastra in...
Page 5: ...mm high with appropriate expansive additive Pic b Take care to cover plates and anchor bolts Pic b 7 Una volta che il palo in posizione e che il getto di materiale di riempimento stato posato fissare...
Page 6: ...tta BA 1 e fissarla alla sottobase mediante viteria a brugola M5 x 12 mm coppia di serraggio 5 Nm Immagine c Lower the BA 1 base cover and fix it to the sub base by means of Allen screws M5 x 12 mm sc...
Page 7: ...m 102mm 114mm Poles diameter 1 Posizionare il palo con interramento seguendo le istruzioni della direzione lavori Place the in ground pole following the instructions of the direction works 2 Una volta...
Page 8: ...Calare la basetta BA 1 e fissarla alla sottobase mediante viteria a brugola M5 x 12 mm coppia di serraggio 5 Nm Immagine b Lower the BA 1 base cover and fix it to the sub base by means of Allen screws...
Page 9: ...d as shown in Pic a 3 Inserire il palo con relativa piastra saldata ed inserire i dadi sui tirafondi sopra la piastra Insert the pole with its welded plate and insert the bolts over the plate on the a...
Page 10: ...sub base plate to the concrete by means of four 14 mm holes 7 Calare la basetta BA 2 e fissarla alla sottobase mediante viteria a brugola M5 x 12 mm coppia di serraggio 5 Nm Immagine c Lower the BA 2...
Page 11: ...o con relativa piastra saldata ed inserire i dadi sui tirafondi sopra la piastra Insert the pole with its welded plate and insert the bolts over the plate on the anchor bolts 4 Sistemare il palo con p...
Page 12: ...mm high with appropriate expansive additive Pic b Take care to cover plates and anchor bolts Pic b 7 Una volta che il palo in posizione e che il getto di materiale di riempimento stato posato fissare...
Page 13: ...tta BA 2 e fissarla alla sottobase mediante viteria a brugola M5 x 12 mm coppia di serraggio 5 Nm Immagine c Lower the BA 2 base cover and fix it to the sub base by means of Allen screws M5 x 12 mm sc...
Page 14: ...7mm 127mm Poles diameter 1 Posizionare il palo con interramento seguendo le istruzioni della direzione lavori Place the in ground pole following the instructions of the direction works 2 Una volta che...
Page 15: ...Calare la basetta BA 2 e fissarla alla sottobase mediante viteria a brugola M5 x 12 mm coppia di serraggio 5 Nm Immagine b Lower the BA 1 base cover and fix it to the sub base by means of Allen screw...