![AE EKA Operation And Maintenance Instructions Download Page 19](http://html.mh-extra.com/html/ae/eka/eka_operation-and-maintenance-instructions_2859424019.webp)
19
Id.Nr.: 228843-13
Electric water heater EKA, EKR, EWH, EKL
EKL
Bold
figures represent the factory connection (6 hrs 230V)
Heater clamping* Heating
time hrs
Heating times at mains voltage
~230V
3~400V
3N~400V
S
8
S+M
6
S+S
4
S+M+S
3 1/3
S+M+S wye conn.
4
3 1/3
3 1/3
Horizontal storage
tank content 80l
kW
A
1,00
6
1,65
10
2,00
10
2,65
10
2,60
6
Horizontal storage
tank content 100l
kW
A
1,10
6
1,75
10
2,20
10
2,85
16
2,80
6
Horizontal storage
tank content 120l
kW
A
1,30
6
1,95
10
2,60
16
3,25
16
3,10
6
Horizontal storage
tank content 150l
kW
A
1,65
10
2,30
16
3,30
16
3,70
10
3,95
10
Horizontal storage
tank content 200l
kW
A
2,10
10
2,75
16
4,40
10
4,85
10
* S = side heater in flange
M = middle heater in flange
15.3 Connection diagram EWH
L, N ....Supply network
Connection voltage ~230V
50 - 150l wall-mounted storage tank 8h
50 - 150l wall-mounted storage tank 6h
50 - 150l wall-mounted storage tank 4h
CAUTION!
Do not change