Calibration of the axes of the AIR50-2230A manipulator
34
Figure 10-1 AIR50-2230A zero point diagram of each axis
Caution
◼
The robot calibration must always be performed at the same temperature
conditions to avoid errors due to thermal expansion and contraction.
◼
The AIR50-2230A industrial robot calibration must be calibrated in
sequence from the J1 axis to the J6 axis.
Calibration required for high repetitive positioning accuracy
During the operation of the manipulator, only when it is required to have higher
repeat positioning accuracy, the positioning accuracy of the path shall not be
required. According to the zero point calibration position shown in Figure 10-1
AIR50-2230A zero point diagram of each axis, the naked eye shall be used to
make the zero point position of each shaft to be aligned, as shown in Figure
J6 Calibration position
J4 Calibration position
J5 Calibration position
J3 Calibration position
J2 Calibration position
J1 Calibration position