Manipulator Manual of AIR20-A Industrial Robot
AIR20-A robot overview and basic composition
6
AIR20-A
Allowable altitude: not more than 1,000m
above sea level
No corrosive, flammable or explosive
gases
Prompt
“
*
”
If the mechanical limit of J1 axle is removed, the range may
reach
-185
°
to 185
°。
2.4
Environmental Requirements for Operation
Temperature
The range of ambient temperature for AIR20-A manipulator is as shown in
Table 2-2 Temperature Limits
Requirement
Value (°
C)
Min. temperature
5
Max. temperature
45
CAUTION
When the ambient temperature is lower than 10
℃
, it is recommended to
heat the engine for a few minutes before use to avoid robot alarm or
performance degradation caused by changes in viscosity of grease.
Humidity
The humidity in the installation environment of manipulator shall not be more
than 95% as specified in "IEC 60721-3-3-2002 Classification of environmental
conditions".
Altitude
The altitude of normal operation environment for manipulator shall not exceed
1,000 m, and the manipulator shall be derated from 1,000 m to 4,000m