background image

7000-SERIES MULTI-AMP CONFIGURATION GUIDE  
 

     

32

 

Information subject to change 

97-8002465_06-09-14

 

 

Figure E-5 – SIM-BNC-OPTOC, Factory Default Settings 

Remove Slave Labels (optional) 

We recommended removing any “Slave” amplifier labels to avoid later confusion or errors.  

Reconfigure SIM-BNC-OPTOC Cards. 

Refer to Figure E-5 for SIM-BNC-OPTOC factory-default settings. Note that for normal stand-alone operation, 
jumpers J6 and J7 (Master/Slave) should be returned to the factory defaults. Stand-alone amplifiers can 
operate with jumpers J4 (Balanced/Unbalanced) and J5 (Ground Lifted/Chassis Ground) set to either 
selection, depending on the user’s preference. Jumpers J12 and J13 (Slave Phase Inversion) are not active 
when a SIM-BNC-OPTOC card is configured for stand-alone/master use, so the setting of this jumpers will not 
affect stand-alone operation. 

7000-Series amplifiers can operate as stand-alone amplifiers using the SIM-BNC-OPTOC as the input card. 
Or, if you prefer, the SIM-BNC-OPTOC card can be removed and the standard SIM-BNC input card re-installed 
for stand-alone use.  

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 7000-Series

Page 1: ...7000 Series Multi Amp Configuration Guide Step by Step Guide to Multi Amp Systems using 7000 Series Amplifiers 574 295 9495 www AETechron com 2507 Warren Street Elkhart IN 46516 ...

Page 2: ...rs 8 3 4 Configure Amplifiers Main Boards for Slave Operation 8 3 5 Remove Output Terminal Resistor 9 3 6 Attach Master Slave Labels optional 9 3 7 Series System Wiring 10 3 8 Two in Series Differential 10 3 9 Two or Three in Series Single Ended 13 4 Parallel Systems Configuration Wiring and Balancing 17 4 1 Install Ballast Resistors 17 4 2 Main Board Access 18 4 3 Disable Gain Controls 7224 ampli...

Page 3: ...last Resistor Connected to Output Terminal 17 Figure 4 4 7796 Ballast Resistors Connected to Output Terminal 17 Figure 4 5 Access Panel Screw Locations 18 Figure 4 6 Gain Control Connection on Main Board 18 Figure 4 7 Gain Control Pin Settings 19 Figure 4 8 Connecting for Balancing Four in Parallel shown 19 Figure 4 9 Terminating the Amplifier Input 20 Figure 4 10 Main Board Balancing Control Loca...

Page 4: ... contact AE Techron Tech Support for assistance with configuring a multi amp system for Controlled Current operation For assistance in determining the best 7000 Series multi amp configuration to meet your requirements please contact AE Techron This Guide will provide step by step instructions for setting up a Series or Parallel controlled voltage multi amp system using AE Techron 7000 Series ampli...

Page 5: ...nectors used to terminate the amplifier inputs during system setup Parallel wiring kits are recommended for all Parallel configurations BNC PARALLEL INPUT KIT Optional kit for wiring parallel inputs through the BNC input connectors instead of the default removable barrier block connectors Each kit contains one BNC patch cable and one BNC T connector Note Now included in parallel wiring kits 1 4 Ac...

Page 6: ...pending on the configuration to be used the OUTPUT terminal of one amplifier should only be directly connected to the next amplifier s COM or SAMPLED COMMON terminal to the load or to a ballast resistor 2 5 When Constructing Output Wiring Use These Basic Criteria In multi amplifier systems the quality gauge length and rating of the output wiring leading to the load can affect system performance Wi...

Page 7: ...that functions to synchronize the operation of all amps in the system and provides for optical isolation The input card allows you to designate via jumpers located on the card that the input card will function as a Master sending synchronization information or will function as a Slave receiving synchronization information Other options for system configuration and operation can also be selected vi...

Page 8: ...e SIM BNC OPTOC input card that is now configured for Slave operation move the shunts 2 positioned on the lower two pins of jumpers J12 and J13 and place them on the UPPER two pins of jumpers J12 and J13 This will allow the input signal received by the Slave amplifier to be inverted If desired configure the Removable Barrier Block input connector option on the Master input card to 3 allow the conn...

Page 9: ...ned off for at least 3 5 minutes and the AC mains are disconnected Turn the power to the amplifier OFF 1 Remove the four hex head screws located along the left and 2 right edges of the amplifier front panel Remove the front cover by pulling straight towards you 3 3 4 3 Set Master Slave Jumpers On the main board locate the jumpers P1 and P2 1 Master Slave For Slave operation set both jumpers to the...

Page 10: ... the back panel AC Mains Switch Circuit Breaker to the ON up position 7548 7796 amplifiers Allow the amplifiers to come to the Ready state When Ready the amplifier Ready and Run LEDs will be lit Note Some amplifiers that have been custom configured may require that you press the Enable button to bring the amplifier to the Ready state Let the amplifiers run for several minutes in Ready state to all...

Page 11: ... the MASTER and SLAVE OUTPUT connectors to your load 2 Power up both amplifiers and allow them to come to the Ready state 3 Apply a sine wave of 5 Vrms at 100 Hz at the Master amplifier input Using a voltmeter measure across 4 the system load to verify an output from the system of approximately 200 Vrms See Figure 3 10 Check the completed system diagram in Figure 3 11 to verify proper system setup...

Page 12: ...7000 SERIES MULTI AMP CONFIGURATION GUIDE 12 Information subject to change 97 8002465_06 09 14 Figure 3 10 Verifying System Gain Figure 3 11 Two Amplifiers in Series Differential Configuration ...

Page 13: ... 7224 amplifiers or moving 5 the back panel AC Mains Switch Circuit Breaker to the ON up position 7548 7796 amplifiers Allow the amplifiers to come to the Ready state When Ready the amplifier Ready and Run LEDs will be lit Note Some amplifiers that have been custom configured may require that you press the Enable button to bring the amplifier to the Ready state Let the amplifiers run for several m...

Page 14: ...D COMMON connector 2 and last SLAVE amplifier s OUTPUT connector to your load Power up all amplifiers and allow them to come to the Ready state 3 Apply a sine wave of 5Vrms at 100 Hz at the Master amplifier input Using a voltmeter measure across 4 the system load to verify an output from the system of approximately 200Vrms See Figure 3 15 Check the completed system diagrams in Figure 3 16 or 3 17 ...

Page 15: ...7000 SERIES MULTI AMP CONFIGURATION GUIDE 97 8002465_06 09 14 Information subject to change 15 Figure 3 15 Verifying System Gain Figure 3 16 Two Amplifiers in Series Single Ended Configuration ...

Page 16: ...7000 SERIES MULTI AMP CONFIGURATION GUIDE 16 Information subject to change 97 8002465_06 09 14 Figure 3 17 Three Amplifiers in Series Single Ended Configuration ...

Page 17: ...teps for each amplifier in your system to install the ballast resistors for Parallel System setup Before preparing the amplifiers make sure the amplifier is turned off for at least 3 5 minutes and the AC mains are disconnected 4 1 Install Ballast Resistors 4 1 1 Mount and Connect Ballast Resistor Locate the bracket mounted ballast resistor s in the 1 Ballast Resistor Kit Position the bracket on th...

Page 18: ...r Remove the Access Panel and set it aside 3 4 2 2 Accessing the Main Board on 7548 7796 Amplifiers The 7548 and 7796 amplifier s main board can be accessed by removing the amplifier front panel IMPORTANT Before removing the Front Panel make sure the amplifier is turned off for at least 3 5 minutes and the AC mains are disconnected 1 Turn the power to the amplifier OFF 2 Remove the four hex head s...

Page 19: ...Note these resistors can be mounted to a header or soldered directly to the pins 4 4 Parallel System Balancing Complete the following procedures to balance your parallel amplifier system 4 5 Connect for Balancing For each amplifier in your system connect a 1 leg of the black output cable found in the Parallel Wiring Kit to one of the amplifier s output connectors labeled COM 7224 or SAMPLED COMMON...

Page 20: ...COM or SAMPLED COMMON to verify that the DC offset of each amplifier is less than 5 mVdc See Figure 4 11 If the DC offset for any amplifier is greater than 5 mVdc adjust each amplifier using the Amp Offset 6 R65 on the amplifier main board Adjust each amplifier s DC offset to read as closely as possible to zero 4 8 Wire and Connect Parallel Inputs IMPORTANT FOR 7224 PARALLEL SYSTEMS In order to en...

Page 21: ...RATION GUIDE 97 8002465_06 09 14 Information subject to change 21 Figure 4 13 Optional BNC Parallel Input Wiring Three in Parallel shown Figure 4 12 Wiring the Paralleled Input Wire Figure 4 11 Wiring and Test Points for DC Offset ...

Page 22: ...ls of the first amplifier 2 See Figure 4 14 Power up the first amplifier 3 Apply a sine wave to the amplifier input of approximately 5Vrms 100 500 Hz This should result in 4 about 100Vrms output from the amplifier assuming a fixed gain of 20 If voltmeter indicates an output greater or lesser than 100 Vrms adjust Amp Gain Trim R210 to correct 5 Power up and repeat this procedure for the second ampl...

Page 23: ...st and the second 1 amplifier see Figure 4 15 Adjust Amp Gain Trim R210 on the second amplifier for minimum AC voltage millivolts 2 Repeat the process of checking gain between the first amplifier and any additional amplifiers in your 3 system Continue checking and adjusting until the gain of all amplifiers in the system is matching to within 4 millivolts Figure 4 15 Wiring and Test Points for Gain...

Page 24: ...vel required for your 4 application 4 12 Verify Current Sharing Power down the amplifiers 1 Connect your load to the two output cables Connect the positive terminal of your load to the red cable 2 connected to the amplifier ballast resistors Connect the negative terminal of your load to the black cable connected to the amplifier COM terminals Check to ensure that all system wiring has been correct...

Page 25: ...7000 SERIES MULTI AMP CONFIGURATION GUIDE 97 8002465_06 09 14 Information subject to change 25 Figure 4 17 Three Amplifiers Paralleled ...

Page 26: ...7000 SERIES MULTI AMP CONFIGURATION GUIDE 26 Information subject to change 97 8002465_06 09 14 Figure 4 18 Four Amplifiers Paralleled ...

Page 27: ...ching requirements of wire gauge and continuous duty amperage limits Minimum value for insulated wire in free air i e not bundled Figure A 1 Wire Current Carrying Capacity Chart Continuous Duty Current Amperes American Wire Gauge AWG Diameter mm Diameter Mils 001 in 200 000 10 40 410 175 00 9 27 365 150 0 8 25 325 125 1 7 35 289 100 2 6 54 258 80 4 5 19 204 60 6 4 12 162 46 8 3 26 128 33 10 2 59 1...

Page 28: ...formation subject to change 97 8002465_06 09 14 Appendix B Critical Wire Lengths in Parallel Systems In Parallel applications the output wiring branches to each amplifier should match within inch Figure B 1 Critical Wire Lengths in Parallel Systems ...

Page 29: ...n determining the requirements for your system IMPORTANT In a paralleled system it is important to control the lengths of output cables Output cables should be between 2 5 and 4 0 feet in length and the lengths of each leg of the output cables should match within 1 4 inch See Appendix B Critical Wire Lengths for information on critical cable lengths for paralleled systems Build two cables for outp...

Page 30: ...ed for the Interlock connections This section describes how to build your own DB 25 cable if you so choose Using DB 25 connectors and light gauge single conductor shielded wire build a cable as shown in 1 Figure D 1 On each connector connect to Pin 4 2 On one of the end DB 25 connectors attach the shield to Pin 17 Label this connector for use on 3 Amplifier 1 in the system Figure D 1 DB 25 Cable W...

Page 31: ...sary Using a 2 Phillips screwdriver remove the 8 screws 2 located on the top and side of the amplifier Remove the Access Panel and set it aside 3 Accessing the Main Board on 7548 7796 Amplifiers The 7548 or 7796 amplifier Main Board can be accessed by removing the amplifier front panel Turn the power to the amplifier OFF 1 Remove the four hex head screws located along the left 2 and right edges of...

Page 32: ... should be returned to the factory defaults Stand alone amplifiers can operate with jumpers J4 Balanced Unbalanced and J5 Ground Lifted Chassis Ground set to either selection depending on the user s preference Jumpers J12 and J13 Slave Phase Inversion are not active when a SIM BNC OPTOC card is configured for stand alone master use so the setting of this jumpers will not affect stand alone operati...

Reviews: