![Adventys Induc-NoLimit KNL4 4000 User And Installation Manual Download Page 42](http://html1.mh-extra.com/html/adventys/induc-nolimit-knl4-4000/induc-nolimit-knl4-4000_user-and-installation-manual_2859165042.webp)
42
FR
EN
Switch off tn cooking zone:
Press the SELECTION key for 3 seconds for the zone you
want to turn off.
Switch off the 4 zonea aimulittneoualiy:
Press for 3 seconds the GLOBAL selection key of the
4 zones.
7
8
DE
Specific meaatge diaplity
The device is perfectly secure. It constantly monitors temperature values and several other electrical pa-
rameters to guarantee the user the highest level of performance and safety at all times.
If during use an incorrect operating status is detected, there may be forced shutdown of the device with
the indication on the power level display, a flashing error code "Fx" or " hx ".
The different codea mtntged by the device tre liiated in the ttblie beliow.
ERROR DESIGNATION
CODE ON DISPLAY
T ° vitro aenaor miaaing or ahort
-
circuited
F1
Eliectronic T ° aenaor miaaing or ahort
-
circuited
F2
Three
-
phtae mtina volittge out of toliertnce
F3
Low volittge auppliy volittge out of toliertnce
F4
Room tempertture aenaor (interntli to the product) miaaing or ahort
-
circuited
F5
Error on controli eliectronica of power trtnaiatora
F6
Probliem connecting ftna (litck of ftn or reverae politrity)
F8
Overhetting vitro
H1 or H3
Overhetting of eliectronic power circuita
H2
Probliem on tempertture aenaor under the vitro
H5
Overhetting of the tmbient tempertture
H6
The flashing error code is displayed as long as the user has not stopped the unit himself and has not re-
started a new start, by using the SELECTION / ON key of the relevant fireplace.
If an error code remains permanently displayed despite several successive acknowledgment attempts,
contact the service department.
If error code F8 is displayed when the generator block is turned on, it indicates a problem with the fans.
Either there is no connection (absence) of 1 or more fans, or there is reverse polarity, or there is overcon-
sumption. You should contact the after
-
sales service and report error F8.
Pending the verdict of the manufacturer, the user has the opportunity to inhibit the error F8 and use the
product in a degraded mode, until the complete correction of the problem.