12
This automatic shut off condition requires user
involvement to restore power to the system.
There is no automatic recovery from over Current
shut off.
To reconnect power to the system, ensure that
the device that caused the over current condition
is not in use or it has been disconnected before
pressing OK.
WARNING:
you run the risk of damaging your
battery, and powered devices if you continue to
try and draw power from the battery.
An internal temperature sensor monitors the
Battery Monitor. If this temperature is greater
than a set threshold it will automatically shut
off the output load to prevent damage to the
electronics inside. This could happen if the
ambient is very high and the system is drawing
high current. You can choose to override the
shut off if you require immediate power.
WARNING:
you run the risk of damaging the
Battery Monitor if you override the shut off.
Alternatively, allow the Battery Monitor to remain
off until the temperature drops to the pre-set
safe limit and it will automatically restore power
to the output loads.
OVER CURRENT
OVER TEMPERATURE
When the Battery Monitor reaches the over Current pre-set value it will automatically shut off the
output load and display the following warning.