61
16 - USE
*HQHUDOLQIRUPDWLRQ
The appliance leaves the factory set with standard
parameters. However, you can consult or make a series
of changes to the parameters through the “user menu”
(section 16.14) and the “installer menu” (section 16.15).
During operation, the display shows the appliance operating
status in addition to other information as described in
section 16.16 (Diagnostics).
16.3 - Display
During normal operation, you can consult further
parameters through the “User menu” (see section 16.14)
that are helpful in understanding appliance operation and
check the latest blocks or errors that have occurred.
After 5 minutes of normal operation, the display switches off
completely to save energy. Simply press any key to switch it
back on. In the event of any anomaly, the display switches
EDFNRQDXWRPDWLFDOO\7KLVIXQFWLRQFDQEHPRGL¿HGE\
following section 16.13 (Energy saving).
16.4 - Ignition and shutdown procedure
To switch ON the appliance, proceed as follows:
1.- open the gas isolation valve;
2.- power the appliance;
3.- If the display shows
Err 65
, it means that phase and
neutral polarity were not respected (call a competent person
WRFKHFNWKHZLULQJZLWKRXWDWWHPSWLQJWR¿[LW\RXUVHOI
4.- adjust the domestic hot water temperature, if any, and the
heating temperature respectively as per sections 16.5,
16.6 and 16.7.
The command and control equipment will ignite the burner. If
ignition is unsuccessful, the appliance automatically attempts
LJQLWLRQ¿YHWLPHVDIWHUZKLFKLILWFRQWLQXHVQRWWRVZLWFKRQLW
locks up and the display will show
Loc 1
along with the
LFRQDQGWKHFRUUHVSRQGLQJÀDVKLQJ
c
d
e
f
burner icon.
Press the RESET key to restore normal operating conditions.
The appliance will automatically attempt another ignition.
$77(17,21 ,I WKH DSSOLDQFH IUHTXHQWO\ VWRSV
EHFDXVH LW ORFNV XS FRQWDFW D FRPSHWHQW SHUVRQ WR
investigate and reset normal operating conditions.
Once started properly, the appliance will continue to work for
the service requested.
To switch OFF the appliance, proceed as follows:
8VHVZLWFK³7´LQ¿JXUHWRFXWSRZHU
2.- close the gas cock;
16.5 - Direct water heater
temperature adjustment
To adjust the temperature, use the
or
keys
VHH¿JXUH
. When the keys are pressed, the display,
SDUW³1´LQ¿JXUHVKRZVWKHUHTXHVWHGWHPSHUDWXUH7KH
instantaneous domestic hot water temperature adjustment
ranges goes from 20°C to 80°C.
$77(17,21 7KH ZDWHU KHDWHU VKRXOG EH
adjusted to ensure that water is stored at a temperature
greater than 60°C and a temperature of 50°C is achieved
at all outlets within 1 minute. Excessive temperatures
VLJQL¿FDQWO\ LQFUHDVH WKH SRVVLELOLW\ RI VFDOGLQJ ZLWK
children and those with a sensory or mobility loss being
at the greatest risk. Where the possibility of scalding
KDV EHHQ LGHQWLILHG DSSURSULDWH PHDVXUHV VXFK DV
thermostatic mixing valves should be considered.
16.6 - Indirect domestic
hot water adjustment
If the appliance is installed for double service (heating and
domestic hot water production), adjust the domestic hot water
temperature using the
and
NH\VVHH¿JXUH
16-1). When the keys are pressed, the display, part “N” in
¿JXUHVKRZVWKHUHTXHVWHG'+:WHPSHUDWXUH7KH
temperature adjustment ranges goes from 40°C to 60°C.
$77(17,21 7KH ZDWHU KHDWHU VKRXOG EH
adjusted to ensure that water is stored at a temperature
greater than 60°C and a temperature of 50°C is achieved
at all outlets within 1 minute. Excessive temperatures
VLJQL¿FDQWO\ LQFUHDVH WKH SRVVLELOLW\ RI VFDOGLQJ ZLWK
children and those with a sensory or mobility loss being
at the greatest risk. Where the possibility of scalding
KDV EHHQ LGHQWLILHG DSSURSULDWH PHDVXUHV VXFK DV
thermostatic mixing valves should be considered.
%RLOHUKHDWLQJDGMXVWPHQW
Adjust the appliance heating temperature using the
or
NH\VVHH¿JXUH
. The room thermostat switches
on the circulation pump in order to meet heating requests.
16.8 - Thermostat type
heating adjustment
The boiler is by default set with parameter
2003
at
0
,
therefore, the boiler supplies the heating system with hot water
at a temperature adjusted using the
and
keys,
Any room thermostats enable or disable the heating function
to adjust the temperature of the rooms. To take full advantage
of boiler performance, it is advisable to adjust the heating
temperature to a value that is just enough to obtain the desired
room temperature. As climatic conditions grow colder, the
heating temperature should be progressively increased. As
the climatic conditions grow warmer, the heating temperature
should be reduced.