R3267 Series Spectrum Analyzer Operation Manual (Vol.1)
3.3.8 FORMAT Key (Display format)
3-42
X Data Mode
Sets the data property for the limit line on the X- axis (frequency
or time).
ABS:
Sets Limit Line position (which is set at Limit Line Ed-
it) on the X-axis to absolute mode.
The Limit Line position on the X-axis varies depending
on the frequency span and center frequency.
REL:
Sets Limit Line position (which is set at Limit Line Ed-
it) on the X-axis to relative mode.
The Limit Line position on the X-axis varies depending
on the frequency span and center frequency.
The Limit Line position on the X-axis is fixed at a loca-
tion specified by "Reference" and "Offset" and is not af-
fected by changes to the frequency span or center
frequency.
Reference
Sets the reference position.
LEFT:
Sets a reference position on the furthest point of the X-
axis.
CENTER:
Sets the reference position to the center of the X-axis.
User Def:
The reference position is set in "User define".
User Define
Sets the reference position on the X-axis.
Offset
Sets the width from the reference position.
Y Data Mode
Sets the data property for Limit Line on the Y- axis (level).
ABS:
Sets Limit Line position (which is set at Limit Line Ed-
it) on the Y-axis to absolute mode.
The Limit Line position on the Y-axis varies depending
on the level.
REL:
Sets Limit Line position (which is set at Limit Line Ed-
it) on the Y-axis to relative mode.
The Limit Line position on the Y-axis varies depending
on the level.
The Limit Line position on the Y-axis is fixed at a loca-
tion specified by "Reference" and "Offset" and is not af-
fected by changes to the level.
Reference
Sets the reference position.
TOP:
Sets the reference position to the highest point on the Y-
axis.