TPC-60S Series User Manual
56
A.2 How to Use the Control Code
There are 6 control codes for the operation codes in the WDT driver.
A.2.1 IOCTL _WDT_ENABLE:
Enables the Watchdog timer on your application. By default, if the
Watchdog timer is enabled, the WDT driver will automatically trigger
itself after the specified period and your application does not need to trig-
ger the Watchdog timer in this situation.
lpInBuffer : unused.
nInBufferSize: unused.
lpOutBuffer: unused.
nOutBufferSize: unused.
A.2.2 IOCTL _WDT_DISABLE:
Disables the Watchdog time on your application.
lpInBuffer : unsed.
nInBufferSize: unused.
lpOutBuffer: unused.
nOutBufferSize: unused.
A.2.3 IOCTL_WDT_STROBE:
Triggers the Watchdog. If your application uses IOCTL_WDT_ENABLE
to enable the Watchdog first and then sends IOCTL_WDT_REBOOT to
the WDT driver, your application must trigger the Watchdog once during
the Watchdog timer period. If your application has not triggered at the
specified period, the device will reboot automatically.
lpInBuffer: unused.
nInBufferSize: unused.
lpOutBuffer: unused.
nOutBufferSize: unused.
Summary of Contents for TPC-60S
Page 1: ...TPC 61S Series ARM9 Touch Panel Computers with 5 7 QVGA STN LCD Dis play User Manual...
Page 8: ...TPC 60S Series User Manual viii...
Page 12: ...TPC 60S Series User Manual xii...
Page 19: ...7 Chapter1 1 8 Exploded Diagram Figure 1 3 Assembly Exploded...
Page 21: ...2 CHAPTER 2 System Setup This chapter provides a brief explana tion for operating the TPC 60S...
Page 53: ...41 Chapter4 Configure the connection setting Figure 4 31 Configure Connection Setting...
Page 65: ...2 APPENDIX A Watchdog Timer Programming...
Page 72: ...TPC 60S Series User Manual 60...
Page 73: ...2 APPENDIX B Fuse Specifications...
Page 75: ...2 APPENDIX C Pin Assignments...