background image

INSTALLATION AND OPERATING MANUAL

40 W Ku-BAND HUB-MOUNT

SOLID STATE POWER BLOCK UP-CONVERTER (SSPB)

SSPB – K40 – CSE

PM 150-23B410-370, Rev. 3

Summary of Contents for SSPB-K40-CSE

Page 1: ...INSTALLATION AND OPERATING MANUAL 40 W Ku BAND HUB MOUNT SOLID STATE POWER BLOCK UP CONVERTER SSPB SSPB K40 CSE PM 150 23B410 370 Rev 3...

Page 2: ...shipping container box with shipping charges prepaid ADVANTECH Advanced Microwave Technologies Inc 657 Orly Avenue Dorval Quebec H9P 1G1 CANADA Please indicate the RMA number on all shipping document...

Page 3: ...5 ALARM INDICATE BOARD 18 3 UNPACKING AND INSTALLATION 19 3 1 INITIAL INSPECTION 19 3 2 UNPACKING 19 3 3 INSTALLATION 19 3 3 1 Mechanical Installation 19 3 3 2 Electrical Connections 20 3 3 3 RF Conne...

Page 4: ...Page 3 6 1 ESSENTIAL OPERATING PROCEDURES 27 7 MAINTENANCE 28 7 1 PREVENTIVE MAINTENANCE 28 7 1 1 Mechanical Preventive Maintenance 28 7 1 2 Checking the Cooling Fan 28 8 APPENDIX E SAFETY AND EMC CO...

Page 5: ...SSPB K40 CSE Page 4 FIGURES FIGURE 1 PRODUCT OUTLINE 12 FIGURE 2 BLOCK DIAGRAM 13 FIGURE 3 CONNECTORS 16...

Page 6: ...CTRICAL SPECIFICATIONS 14 TABLE 2 MECHANICAL SPECIFICATIONS 15 TABLE 3 POWER REQUIREMENTS 15 TABLE 4 ENVIRONMENTAL CONDITIONS 15 TABLE 5 CONNECTORS 17 TABLE 6 AC LINE J5 PIN ASSIGNMENTS 17 TABLE 7 DIS...

Page 7: ...TRANSMITTING EQUIPMENT also Sub clauses 3 2 3 7 and 22 1 of the Standard To prevent the risk of personal injury or loss related to equipment malfunction Advantech uses the following symbols for safet...

Page 8: ...on there is a risk of damage to precision components WARNING ALWAYS TERMINATE THE OUTPUT WAVEGUIDE OF THE UNIT WITH AN RF LOAD CAPABLE OF DISSIPATING FULL CW RF POWER Incorporate the termination prior...

Page 9: ...y vulnerable parts of your body The permissible levels of exposure are quite low in comparison to the power levels of the equipment built by Advantech e g less than 10 mW versus 4 to 700 W delivered b...

Page 10: ...d in whole or in part as the basis for manufacturing or sale of the equipment or software programs without the prior written consent of ADVANTECH Advanced Microwave Technologies Inc 2 2 DESCRIPTION Th...

Page 11: ...riate up converter term which in turn drives a Solid State Power Amplifier SSPA Integral to this module there is a variable attenuation section used for global temperature compensation 2 2 3 HPA ASSEM...

Page 12: ...70 Rev 3 2 1 Ku Band 40 Watt SSPB model SSPB K40 CSE 150 23B410 370 3 4 6 32 x 1 2 hex head screw 802 632090 001 4 4 6 lock washer 803 600100 001 5 1 MS3106F 10SL 3S Connector for J5 631 310610 001 6...

Page 13: ...SSPB K40 CSE Page 12 Figure 1 Product Outline...

Page 14: ...SENSOR 12V 9V 12V 9V POWER CONDITIONER BOARD ASSEMBLY HPA 12V high current ISOLATOR HPA ASSEMBLY UP CONVERTER GND J3 DISCRETE INTERFACE MUTE J5 AC LINE C B A OUTPUT WAVEGUIDE COOLING FAN PLL LO 2 175...

Page 15: ...ion Over Temperature 3 dB pk pk over the entire bandwidth L Band Input Impedance 50 L Band Input Return Loss 15 dB min Output Return Loss 20 dB min Noise Figure 15 dB typical Spurious at rated P1dB 60...

Page 16: ...ge 12 TABLE 3 POWER REQUIREMENTS Power Requirements 90 132 or 180 264 VAC autoranging 47 63 Hz single phase Power Consumption 6 A typical 110 VAC TABLE 4 ENVIRONMENTAL CONDITIONS Temperature Non opera...

Page 17: ...SSPB K40 CSE Page 16 Figure 3 Connectors...

Page 18: ...ter Input N Type F N Type M J3 Discrete Interface MS3112E16 26P M MS3116F16 26S F J4 RF Output Monitor Port N Type F N Type M J5 AC Line MS3102R 10SL 3P M MS3106F 10SL 3S F J7 Waveguide Output WR 75 F...

Page 19: ...Form C relay contacts Fault Alarm Out of lock and Output Power Level monitoring Mute mode which may be asserted by a remote current mode MUTE signal A 20 mA current may be optionally either MUTE or EN...

Page 20: ...all items listed on the packing list have been received Inspect all items for evidence of damage in shipment If damage seems evident immediately contact the carrier that delivered the equipment and f...

Page 21: ...page 16 User needs Type N male on interface connection RF output J7 WR 75 waveguide flange flat see Figure 1 Product Outline page 12 User needs WR 75 waveguide flange grooved CAUTION Beware of destru...

Page 22: ...e power amplifier and thus allowing for a variable temperature dependent rotation speed of the cooling fan Depending on environmental conditions the airflow opening may become obstructed by debris red...

Page 23: ...command and status 2 RF Output Monitor Interface J4 This interface provides a measure of the output power of the amplifier Interface connectors for these devices are located at the connector plate of...

Page 24: ...se FAULT state K FAULT NO Normal open contact of the FAULT Form C relay When open FAULT state L MUTE Input Negative side of the optocoupler input M N C Not connected N COM Common P PWR MONITOR Output...

Page 25: ...ed its normal closed contacts will be connected to the common terminal This will indicate FAULT condition on the customer interface the unit will be in shut down A Temperature ALARM signal is internal...

Page 26: ...d in the MUTE mode caused by external mute signal to avoid a false FAULT 4 2 RF OUTPUT MONITOR PORT This RF interface is located at J4 connector of SSPB It is typically used for independent monitoring...

Page 27: ...are tight no wires are pinched and no other hardware has been loosened during handling The main power switch on the prime power station is turned OFF The RF Input and RF Output are connected to a mat...

Page 28: ...or alarm messages are active on the Discrete Interface 4 Ensure that the L Band input signal is applied to the SSPB 5 Provide the connection between pins N and L at the discrete interface J3 in order...

Page 29: ...us breakage deterioration excess moisture and mounting integrity 5 Periodically depending on environmental conditions a cleaning of the heat sink is necessary do not allow debris dust or other substan...

Page 30: ...5kV Signal Lines 1 kV Power Lines IEC 1000 4 4 EN 50082 1 1998 Electrostatic Discharge contact and air discharge 4kV CD 8 kV AD IEC 1000 4 2 EN 50082 1 1998 Surge Immunity AC ports 1kV 0 5 kV IEC 100...