SmartFlex SR309
7. Technical Parameters
7.1
Basic parameters
SmartFlex Router
Temperature range
Operating
Storage
-40
◦
C to +75
◦
C (-40
◦
F to +167
◦
F)
-40
◦
C to +85
◦
C (-40
◦
F to +185
◦
F)
Cold start
-35
◦
C
-40
◦
C
Data transfers via mobile network are available
immediately
Data transfers via mobile network are avail-
able approximately five minutes after the start
of the router. Everything else is functional im-
mediately.
Humidity
Operating
Storage
0 to 95 % relative humidity non condensing
0 to 95 % relative humidity non condensing
Altitude
Operating
2000 m / 70 kPa
Degree of protection
IP30
Supply voltage
10 to 60 V DC
Battery for RTC
CR1225
Consumption
Idle
Average
Peak
Sleep mode
2.5 W
4 W
11 W
10 mW
Dimensions
55 x 97 x 125 mm (2.17" x 3.82" x 4.92")
(DIN 35 mm, EN 60715)
Weight
Plastic box
Metal box
approximately 170 g (0.37 lbs)
(depends on interface)
approximately 380 g (0.83 lbs)
(depends on interface)
Antenna connectors
3x SMA – 50
Ω
1x R-SMA – 50
Ω
(only for versions with WiFi)
User interface
2x ETH
USB
I/O
Micro SD
Ethernet (10/100 Mbps)
USB 2.0
6-pin panel socket
SDHC, SDXC
Table 21: Basic parameters