background image

 

Installing SCSI driver for Windows NT 4.0 

 

Driver Install during Windows NT Installation 

 

1. CD-ROM Install: Boot from the CD-ROM of Win NT 4.0 

and press 

<F6>

 while the message “

Setup is inspecting 

your computer’s configuration…

”. 

2. When the “

Windows NT Setup

” window is generated, 

select “

Other

” and press “

Enter

”. 

3. Insert the “

Adaptec 7899 SCSI Driver for Win NT 4.0

” 

diskette into Drive A: and press "

ENTER

". 

4. Select  the  “

Adaptec 19160, 29160(N), 39160, 

AHA-3960D, AIC-7892/7899 Ultra160 PCI SCSI 

Controller (NT 4.0)

” and click “

OK

”. 

 

Follow the normal Windows NT 4.0 setup installation 

procedure. 

 

 

 

 

 

 

 

 

 

RS-200-RT User’s Manual 

75

Summary of Contents for RS-200-RT

Page 1: ...User s Manual RS 200 RT 2U Server...

Page 2: ...the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements...

Page 3: ...ks are properties of their respective owners CE Notification RS 200 RT R3 R3 RS 200 RT S3 S6 RS 200 RT R3 S6 and RS 200 RT TB developed by Advantech Co Ltd has passed the CE test for environment speci...

Page 4: ...allation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customer...

Page 5: ...your product is diagnosed as defective obtain an RMA return merchandise authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product...

Page 6: ...r Bank 4 Driver Bank Floppy Diskettes including RAID RS 200 RT User s Manual Warrant Card Holder for full size Add on Card 2 Screw sinks for holder Technical Support and Sales Assistance If you have a...

Page 7: ...ystem Placement 31 2 2 Motherboard Placement 32 2 3 SCSI Backplane Placement 35 2 4 Installing CPU 37 2 5 Installing CPU Cooler 40 2 6 Installing System Memory 43 2 7 Installing Add on Cards 45 2 8 In...

Page 8: ...t without Saving 72 Chapter 4 Drivers Installation 73 4 1 Drivers for Windows NT 4 0 74 4 2 Drivers for Windows 2000 77 4 3 Drivers for Red Hat Linux 7 0 7 1 79 Appendix A Memory Approval List 81 Appe...

Page 9: ...RS 200 RT User s Manual 8...

Page 10: ...ed to compete at the forefront in this fast paced product sector Thin servers are rapidly becoming the platform of choice for Internet VOD Video on Demand industrial and telecom focused applications C...

Page 11: ...ppable SCSI storage devices high speed network interfaces and specially designed fault detection and management features These all add up to a hardware solution that provides the kind of high availabi...

Page 12: ...nnel controller data transfer rate up to 160MB s Each channel can support 3 internal SCSI HDD RAID HW zero channel RAID module option LAN Triple Intel 82559 Fast Ethernet controllers support 10 100Mbp...

Page 13: ...bays 1 slim type FDD drive and 1 slim type CD ROM drive Power Supply Redundant 300W 1 1 power supply Input 90 264VAC Full Range 47 63Hz System Monitoring Integrated server management features includi...

Page 14: ...Dimension 482mm 19 W x 88mm 3 46 H x 600mm 23 6 D Certifications FCC Class A CE UL CUL BSMI OS Linux Free BSD 4 x Win 2K NT 4 0 Solaris 8 x RS 200 RT User s Manual 13...

Page 15: ...ata transfer rate up to 160MB s One channel can support 6 internal SCSI HDDs RAID HW zero channel RAID module option LAN Triple Intel 82559 Fast Ethernet controllers support 10 100Mbps with RJ 45 conn...

Page 16: ...CSI HDD drive bays 1 slim type FDD drive and 1 slim type CD ROM drive Power Supply Redundant 300W power supply Input 90 264VAC Full Range 47 63Hz System Monitoring Integrated server management feature...

Page 17: ...Storage Humidity5 95 Dimension 482mm 19 W x 88mm 3 46 H x 600mm 23 6 D Certifications FCC Class A CE UL CUL BSMI OS Linux Free BSD 4 x Win 2K NT 4 0 Solaris 8 x RS 200 RT User s Manual 16...

Page 18: ...data transfer rate up to 160MB s One channel can support 6 internal SCSI HDDs RAID HW zero channel RAID module option LAN Triple Intel 82559 Fast Ethernet controllers support 10 100Mbps with RJ 45 co...

Page 19: ...A 2 SCSI HDD drive bays 1 slim type FDD drive and 1 slim type CD ROM drive Power Supply 300W power supply Input 90 264VAC Full Range 47 63Hz System Monitoring Integrated server management features inc...

Page 20: ...Storage Humidity5 95 Dimension 482mm 19 W x 88mm 3 46 H x 600mm 23 6 D Certifications FCC Class A CE UL CUL BSMI OS Linux Free BSD 4 x Win 2K NT 4 0 Solaris 8 x RS 200 RT User s Manual 19...

Page 21: ...r rate up to 160MB s Each channel can support 3 internal SCSI HDD RAID HW zero channel RAID module option LAN Triple Intel 82559 Fast Ethernet controllers support 10 100Mbps with RJ 45 connectors One...

Page 22: ...e DVD ROM drive Power Supply 300W power supply with UPS Input 110V 220V VAC 47 63Hz System Monitoring Integrated server management features including thermal voltage fans and power failure monitoring...

Page 23: ...Certifications FCC Class A CE UL CUL BSMI OS Win 2K NT 4 0 Linux RS 200 RT User s Manual 22...

Page 24: ...ces User can plug USB device directly to the USB connector LAN Connectors 8 pin The serverboard provides three LAN connectors with two status LEDs One LED indicates whether 100Mbit protocol is active...

Page 25: ...nded capabilities Parallel Port ECP PS 2 Mouse Connector 6 pin Female The connector is for a standard PS 2 mouse only Serial Port Connector The serverboard has one 9 pin male DIN connector for RS 232...

Page 26: ...e Red Voltage Redundant Power Failure Temperature Red Overheating Fan Red Fan Failure LAN 1 Green Active LAN 2 Green Active LAN 3 Green Active Green Active HDD 1 Red HDD failure Green Active HDD 2 Red...

Page 27: ...ator Description Voltage Red Voltage Redundant Power Failure Temperature Red Overheating Fan Red Fan Failure LAN 1 Green Active LAN 2 Green Active LAN 3 Green Active Green Active A ID 1 Red HDD failur...

Page 28: ...1 4 Rear Panel 64 bit PCI slot port 32 bit PCI slot port Power Supply RS 200 RT User s Manual 27...

Page 29: ...problem is solved Temperature monitoring and alert To prevent system from overheat and damage the server board supports processor thermal sensing and auto protection If an alert is triggered that mea...

Page 30: ...ailure status If an alert is triggered that means a failure status occurs The system will signal a red light on the front panel and the buzzer will sound to alert Even if the Alarm Reset button and th...

Page 31: ...RS 200 RT User s Manual 30...

Page 32: ...Chapter 2 System Placement and Installation 2 1 System Placement Power Supply Motherboard CD ROM FDD HDD FAN DVD ROM RS 200 RT User s Manual 31...

Page 33: ...Ch B Power module P CPU0 socket CPU1 socket FDD port IDE port Power Connector SCSI Chip SCSI Port Ch A FDD Port VGA Chip CD ROM Port Southbridge Note If machine installs one CPU only please insert it...

Page 34: ...d System Reset For LED board system reset bottom S2 J6 LAN1 LAN2 LED indicator Function Jumper On board 82559 LAN1 LED PIN 1 2 Closed On board 82559 LAN2 LED PIN 3 4 Closed On board 82559 LAN3 LED PIN...

Page 35: ...Ghz 10 OFF ON OFF OFF 1 33Ghz 10 5 ON ON OFF ON 1 4Ghz 11 ON OFF OFF OFF 1 46Ghz 11 5 OFF ON OFF ON 1 53Ghz 12 ON OFF OFF ON 1 6Ghz Note1 Case Fan must connect to CN27 FAN 2B0 CN28 FAN 2B1 CN29 FAN 2B...

Page 36: ...CN1 68 pin SCSI Connector to Host CN3 SCSI HDD Active Indicator CN4 Power Connector CN5 SCA 2 SCSI HDD Connector ID 5 CN6 SCA 2 SCSI HDD Connector ID 6 CN7 SCA 2 SCSI HDD Connector ID 4 CN8 SCA 2 SCSI...

Page 37: ...or to Host CN4 Power Connector CN5 SCA 2 SCSI HDD Connector Ch A ID 1 CN6 SCA 2 SCSI HDD Connector Ch A ID 3 CN7 SCA 2 SCSI HDD Connector Ch B ID 2 CN8 SCA 2 SCSI HDD Connector Ch B ID 3 CN9 SCA 2 SCS...

Page 38: ...CPUs should be The same type The same speed Before installing the CPU check it for any visible damage Make sure none of the pins are bent or missing To install the CPUs first turn off your system rem...

Page 39: ...r of CPU socket to a position perpendicular to the socket up Orient the CPU to the socket correctly so that the pins match the receptacles Insert the CPU in the socket so that the pins fully insert RS...

Page 40: ...install one CPU it is necessary to install an optional CPU terminator in another slave CPU socket The procedure of installing CPU terminator is the same as CPU Warning Without a fan or heat sink a CPU...

Page 41: ...per cooling device for the CPU The server comes with two high efficiency heatsink CPU coolers that sit on the top of an installed CPU and clip onto the CPU socket The general procedure is Take out the...

Page 42: ...lace the clip to hold the protrusion on another side of CPU socket Press the spring clip over the protrusion so that it snaps in place Plug the power connector of CPU cooler fan into power socket CN17...

Page 43: ...d CPU cooler fan Please use extra caution when installing any type of clamp style fan or else damage may occur to the CPU socket and or the CPU itself Note In order to upgrade to support higher speed...

Page 44: ...r specification table Always observe static electricity precautions when installing memory To install DIMM modules do as follows Press the socket retaining latches back out of the way Orient the modul...

Page 45: ...the side of the module Repeat this operation for the rest of modules you will install Note Serverworks III LE chipset can support system memory size up to 4GB but it depends on OS support It means if...

Page 46: ...o install up to 2 64bit 66MHz PCI add on cards in the expansion slots The detailed installation procedure is stated as follows Remove the pre installed bracket so that add on card bracket can be inser...

Page 47: ...Fasten the bracket of the add on card with screw RS 200 RT User s Manual 46...

Page 48: ...on Main Board and fasten it with M3 screw Please refer to 2 2 Main Board Placement for LAN module location The system is equipped with 3 high performance 32 bit PCI bus Ethernet interfaces which are f...

Page 49: ...inexpensive and optional hardware RAID solution without sharing extra PCI slot Insert the zero channel hardware RAID module into RAID module socket with 30 degree angle Please press the module down a...

Page 50: ...can support three six hot swap hard disk drives Please notice that if the hard disk drives used in the RS 100 200 RT shall be 3 5 1 height SCSI hard disk drives with 80 pin SCA 2 connectors In order t...

Page 51: ...Hard Disk drive assembled Slide the cages of the HDD drive into HDD bays and make HDD drive connectors connect the SCSI sockets on SCSI backplane closely Close the latches RS 200 RT User s Manual 50...

Page 52: ...2 11 Installing Rail Slider RS 200 RT User s Manual 51...

Page 53: ...RS 200 RT User s Manual 52...

Page 54: ...tings as they come from the factory If you want to check or alter BIOS settings run the CMOS Setup Utility by pressing the Del key command during the POST If you think the settings need to be refreshe...

Page 55: ...e described as below Key Function Description Esc Jump to Exit menu or return to the main menu from sub menu or Move the cursor to the up or down between fields or Select the menu item to the left or...

Page 56: ...3 2 Main Menu When the Setup program is accessed the following screen appears Move arrow keys to the appropriate place you will setup and press Enter for selection RS 200 RT User s Manual 55...

Page 57: ...gure system components such as date time hard disk drive and floppy drive types showed in the screen below Date mm dd yy Set the system date The format is month day and year Move to proper place by ar...

Page 58: ...imary Master Move the highlight to the IDE Primary Master and enter to get the following screen IDE HDD Auto Detection To auto detect the capacity cylinder head and sector of HDD RS 200 RT User s Manu...

Page 59: ...IDE Primary Master Auto Manual None Access Mode Auto Large LBA CHS RS 200 RT User s Manual 58...

Page 60: ...the option then get the following three items IDE HDD Auto Detection To auto detect the capacity cylinder head and sector of HDD IDE Secondary Master Auto Manual None Access Mode Auto Large LBA CHS ID...

Page 61: ...A Set the type of floppy drive installed by Page Up Key and Page Down Halt On Set system halt on when specified item occurs The selection items are showed in the following screen RS 200 RT User s Manu...

Page 62: ...to skip certain tests while booting This will decrease the time needed to boot the system First Boot Device Floppy SCSI CD ROM HDD LAN Disabled Select your boot device priority Second Boot Device Flo...

Page 63: ...B type drive is 40 tracks while 720 KB 1 2 MB and 1 44 MB type drives are all 80 tracks Disable BIOS will not search for the floppy drive type by track number Gate A20 Option Fast Normal Fast let chip...

Page 64: ...he setting determines whether the system will boot up if the password is denied Access to Setup is however always limited System The system will not boot and access to Setup will be denied if the corr...

Page 65: ...e user must choose which channels to disable This will depend on the channel used in the PCI Off Board add on card IDE Primary Master Slave PIO Auto Mode0 Mode 1 4 Each channel has both a master and a...

Page 66: ...eyboard without device driver IDE HDD Block Mode Enabled Disabled Enabled allows the Block mode access for the IDE HDD Onboard FDC Controller Enabled Disabled The system has an on board Super I O chip...

Page 67: ...On board serial ports can be selected as Auto Disable 3F8 IRQ4 COM 1 uses IRQ4 2F8 IRQ3 COM 2 uses IRQ3 Reserved for Internal Alarm Board 3E8 IRQ4 COM 3 uses IRQ4 2E8 IRQ3 COM 4 uses IRQ3 ECP Mode Us...

Page 68: ...led Select Enabled to reset Extended System Configuration Data ESCD when you exit Setup if you have installed a new add on and the system reconfiguration has caused such a serious conflict that the OS...

Page 69: ...d should correct this problem Otherwise leave this on the setup default setting of Disabled Recommend set Disabled State After Power Failure The field let you determine which state your PC with a powe...

Page 70: ...load the optimized default values for each of the parameters on the Setup menus When this option is pressed a confirmation is requested Select Y to load the optimized default values Select N or Press...

Page 71: ...press Enter You can type up eight alphanumeric characters If the CMOS is good or if this option has been used to change the default password the user is asked for the password stored in the CMOS The s...

Page 72: ...he option to save the values you selected to CMOS RAM The CMOS RAM is sustained by an on board backup battery and stays on even system is turned off Once the option is selected a confirmation is asked...

Page 73: ...e used if you do not want to save the changes you have made to the Setup program If you have made changes to the fields the system will ask for confirmation before existing Select Y then the system wi...

Page 74: ...d drivers from the website http access1 sun com patch public cgi bin show_list cgi un b Solaris_x86_Intel_Drivers The server provides an optional zero channel hardware RAID module that can support RAI...

Page 75: ...below when running Setup or CD auto run VGA driver installation Please select the item RS200 RT Drivers Please click Install VGA driver then Choose NT4 Double click setup exe Please follow the instruc...

Page 76: ...computer s configuration 2 When the Windows NT Setup window is generated select Other and press Enter 3 Insert the Adaptec 7899 SCSI Driver for Win NT 4 0 diskette into Drive A and press ENTER 4 Selec...

Page 77: ...ase finish Win NT 4 0 SP6 installation first 2 Double click My Computer icon 3 Select Control Panel icon 4 Choose SCSI Adapter icon 5 Press Drivers 6 Press Add under Drivers selection 7 Specify a inse...

Page 78: ...nstallation Please select the item RS200 RT Drivers Please click Install VGA driver then Choose Win2000 Double click setup exe Please follow the instructions showed on the screens Restart after driver...

Page 79: ...tup Method dialog box press Enter to confirm Express Setup 4 Press S to add a SCSI adapter 5 Specify a insert the Adaptec I2O RAID Host Adapters for Windows 2000 diskette into Drive A and press ENTER...

Page 80: ...Linux 7 0 7 1 2 When system shows Boot please type linux dd 3 When it shows Do you a driver disk Please choose Yes 4 When it shows Insert your driver disk please press OK 5 Then follow the instruction...

Page 81: ...RS 200 RT User s Manual 80...

Page 82: ...2284578E83R SAMSUNG 1GB 5 ATP AR16V72C4S4GAS SAMSUNG KM44S16030CT G7 128MB 6 ATP AR32V72C4S4GAS SAMSUNG K4S280432A TC75 256MB 7 ATP AR64V72C4S8GAS SAMSUNG K4S560432A TC75 512MB 8 ATP AR128V72C4SSGAS S...

Page 83: ...ress 500 Series 475 3 Mylex AcceleRAID 170 4 Mylex AcceleRAID 352 Appendix C Accessory order information No P N Description 1 9686000073 ZCR HW RAID module 2005S 2 96960210A0 LAN module for 3rd LAN po...

Page 84: ...convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting equipment to the power outlet 9 Position the power...

Page 85: ...ged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 4 OR ABOVE 60 140 THE MAY DAMAGE THE EQUIPMENT...

Page 86: ...ngen hervorrufen 7 Die Bel ftungs ffnungen dienen zur Luftzirkulation die das Ger t vor berhitzung sch tzt Sorgen Sie daf r da diese ffnungen nicht abgedeckt werden 8 Beachten Sie beim Anschlu an das...

Page 87: ...t der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Ger t ist gefallen und oder das Geh use ist besch digt f Wenn das Ger t deutli...

Page 88: ...click My Computer icon 2 Select Control Panel icon 3 Choose Administrative Tools icon 4 Choose Computer Management icon 5 Choose Device Manger icon 6 You can choose the SDR GEM318 SCSI Processor Devic...

Reviews: