7
PPC-IPS User Manual
C
ha
pte
r 2
In
sta
lla
tio
n I
ns
tru
ctio
ns
2.2
Dual Auto-Shutdown Modes
*In max. power mode, the PPC-IPS module optimizes power consumption to support a maxi
-
mum length of time based on the remaining battery capacity.
Note!
Customers can select the mode according to their usage requirements.
SW Utility via RS-232
HW via PS_ON
Installation Procedures
Connect the PPC-IPS
module to the PPC
device using a RS-232
cable
Install SW utility
Configure the timing
and shutdown mode (S4
or S5) settings in the
SW utility (refer to
Chapter 4.2)
Connect the PPC-IPS mod
-
ule to the PPC device using
a PS_ON cable
Set the time switch on the
PPC-IPS module (see Fig.
2.2, item E)
Configure the shutdown
mode (S4 or S5) in the OS
(refer to Chapter 3.2)
Settings
Time to shut
down PC after
power outage
5~ 360 seconds (per second) 30 or 360 seconds
(set via external switch)
Time to turn-off
IPS after shut-
down command
1~ 9 minutes (per minute)
Not supported
Operating System
Windows 10, XP, 7, 8, and 8.1 Windows 7, 8, 8.1, and Linux
Compatible Products
The standard software utility
is only available for PPC
series systems, but can be
customized for other devices
upon request
Only available for PPC series
systems
Accessories
RS-232 cable
PS_ON cable
Advantages
Time ranges can be
configured
Supports max. power
mode*
Status monitoring
Plug-and-play functionality
No software installation
No RS-232 port required
Summary of Contents for PPC-IPS
Page 1: ...User Manual PPC IPS Intelligent Power System for PCs ...
Page 6: ...PPC IPS User Manual vi ...
Page 9: ...Chapter 1 1 General Information Introduction Specifications Dimensions ...
Page 13: ...Chapter 2 2 Installation Instructions ...
Page 30: ...PPC IPS User Manual 22 ...
Page 31: ...Chapter 3 3 IPS Settings 3 1 I O Connector Specifications ...
Page 37: ...Chapter 4 4 PPC IPS AE Adjustment Tool ...
Page 41: ...33 PPC IPS User Manual Chapter 4 PPC IPS AE Adjustment Tool ...