background image

User Manual

POC-IPSM90PS

Point-of-Care Intelligent Power 
System

Summary of Contents for POC-IPSM90PS

Page 1: ...User Manual POC IPSM90PS Point of Care Intelligent Power System...

Page 2: ...ctions in an easy to follow sequence Definitions Part No 200890PS00 Edition 1 Printed in Taiwan December 2019 Warning A WARNING statement provides important information about a poten tially hazardous...

Page 3: ...f one of the following occurs have the equipment checked by qualified service personnel The power cord or plug is damaged Liquid has penetrated the equipment The equipment has been exposed to moisture...

Page 4: ...g from the socket The power supply is regarded as part of this equipment 5 Do not use the battery if the battery pack is damaged Caution 1 Contact a qualified technician or your retail provider for ba...

Page 5: ...to correct the interference by one or more of the follow ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment t...

Page 6: ...irements to dispose of unit Manufacturer Advantech Co Ltd No 1 Alley 20 Lane 26 Rueiguang Road Neihu District Taipei Taiwan 114 R O C TEL 02 2792 7818 Distributed in Europe by Advantech Europe GmbH Ko...

Page 7: ...t Specifications 9 Table 2 1 DC In DC Out Specifications 9 2 2 1 DC IN Pin Definition 10 2 2 2 DC Out Pin Definition 11 2 3 COM Output Specifications 11 2 3 1 COM Pin Definition 12 2 4 Installation Pr...

Page 8: ...POC IPSM90PS User Manual viii...

Page 9: ...Chapter 1 1 General Information...

Page 10: ...Pack Capacity 90Wh each total 270Wh 2 or 3 hot swappable batteries support 6 12 hours operation depending on power consumption Battery Life Cycle Time 300 cycle time 70 normal capacity Charge Time Sin...

Page 11: ...ght 4 kg 8 81 lb POC IPSM90PS with three battery packs Dimensions Dimensions W x D x H 563 8 x 125 x 76 5 mm 22 19 x 4 92 x 3 01 in Certification Certification Power system IEC60601 1 2 fourth edi tio...

Page 12: ...POC IPSM90PS User Manual 4 1 3 Dimensions The system dimensions are 563 5 x 125 x 76 5 mm 22 18 x 5 52 x 3 01 in Unit mm...

Page 13: ...5 POC IPSM90PS User Manual Chapter 1 General Information...

Page 14: ...POC IPSM90PS User Manual 6...

Page 15: ...Chapter 2 2 System Setup...

Page 16: ...amiliarize yourself with the various functions of the system connectors switches and ports which are shown below 2 1 1 Front view Figure 2 1 POC IPSM90PS Front View 2 1 2 Rear View Figure 2 2 POC IPSM...

Page 17: ...25V Rating 19V input Adapter Delta MDS 150AAS19 BJ 19V 150W DC Out According to switch settings 12V 17V 19V 24V Factory shipping default 12V see Note 2 below Output power 90W max Note The DC In voltag...

Page 18: ...closure cover for users to reference before adjustment The 19V output setting is as shown below 2 2 1 DC IN Pin Definition DC In uses Amphenol A00 MSAS 05PMR SF703 male pin type Pin Number Function No...

Page 19: ...ut uses Amphenol A00 MSAS 05PFR SF703 female hole type 2 3 COM Output Specifications Note Confirm the key direction to identify pin 1 Pin Number Function Note 1 Return GND 2 Return GND 3 DC Out 4 DC O...

Page 20: ...s below to install and setup the system Step 1 Remove the AC power cord and battery packs Step2 Configure the DC output voltage via the switch Pin Number Function Note 1 GND 2 GND 3 GND 4 Reserved Rem...

Page 21: ...VESA mount plate marked in red below 2 Slide the POC IPSM90PS power system onto the AMiS arm 3 The POC IPSM90PS VESA bracket will fit the AMiS arm Use four screws to affix the POC IPSM90PS system to t...

Page 22: ...DC Out and COM cables from the POC IPSM90PS to the DC In DC Out and COM ports of the POC terminal Step 4 Turn the cable screw lock clockwise to lock the three cables into their sockets the cable plug...

Page 23: ...ow to indicate the correct installation direction Users can access the battery slot using the arrowhead buttons circled in red below Note Lay the pull ring and mylar indicated in the image below flat...

Page 24: ...witch when the power is turned on green LED or the POC IPSM90PS system is in use as this may damage the components and or POC terminal Note If the power adapter is plugged into the POC IPSM90PS system...

Page 25: ...Chapter 3 3 Battery Maintenance...

Page 26: ...rged battery or plug in the power adaptor to recharge the battery Figure 3 1 Low Battery Alert 3 If the battery over discharges shutting down the POC terminal or connected devices the battery must be...

Page 27: ...a tor is off 3 3 Troubleshooting 1 If pressing the Power On Off button does not switch on the DC Out function the green LED indicator remains off follow the steps outlined below a Check that the power...

Page 28: ...software battery app cannot read battery capacity follow the steps outlined below a Check that the COM cable right port is connected and the screw lock is fastened tightly the cable plug type may diff...

Page 29: ...llow the steps outlined below a Check that the battery pack is correctly installed and fully inserted in the bat tery slot b Check that the DC IN cable is correctly connected NOTE With this battery de...

Page 30: ...POC IPSM90PS User Manual 22...

Page 31: ...Chapter 4 4 Operating and Safety information...

Page 32: ...adapter cable Ensure that at least one end of the power adapter cable is within easy reach to enable unplugging when necessary Warning 1 Temperatures that are too high or too low may damage the batter...

Page 33: ...er is a medical grade adapter Warning 1 Li ion battery packs may explode and cause fire if defective or used incorrectly To prevent this from happening follow all usage instruc tions and safety guidel...

Page 34: ...ng metal or a wire lead 5 Do not drop the battery pack 6 Do not expose the battery pack to fire or high temperatures Warning 1 Do not insert non Advantech battery packs into the POC IPSM90 power syste...

Page 35: ...by Advantech 14 Use discharge the battery pack in indoor environments with a controlled temper ature 15 Inspect all battery packs before use Warning Batteries are at risk of exploding and may cause f...

Page 36: ...emove the battery pack from the device if the device will be unused for several months 5 Do not remove individual battery packs from the original packaging until required for use Caution When the time...

Page 37: ...eries come into contact with other batteries or metal objects the remaining stored energy may be discharged and cause a fire or explosion Guidance and Manufacturer s Declaration Electromagnetic Emissi...

Page 38: ...V line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commer cial or hospital environment Power frequency 50 60 Hz magnetic...

Page 39: ...31 POC IPSM90PS User Manual Chapter 4 Operating and Safety information...

Page 40: ...e subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permiss...

Reviews: