PCM-3680 Startup Manual
3
Software Overview
The PCM-3680 comes with a utility disk with the fol-
lowing software capabilities:
• CAN controller configuration
• CAN transmission monitoring
• Terminal emulation
Main Menu
Run DataMonitor at the DOS prompt. DataMonitor's
main menu screen will appear as shown below
The main screen consists of:
A.
Menu bar:
Lists the available functions. From the
main menu you can select Configuration, Monitoring,
and Terminal.
B.
Monitor screen:
Shows monitored data, including
message index, CAN device ID, data length, and data.
C.
Status fields:
Display the status of the two ports
and the status register of the CAN controllers.
D.
Online help/message bar:
Shows various key
commands and states the function of the currently high-
lighted item.
Configuration
Before you transmit a CAN object, you must configure
the CAN controller by selecting the <Config> menu
with the cursor keys and pressing <Enter>. The Config-
uration function determines the ports to be used and
their communication parameters.
The port configuration window is shown below.
The parameters below need to be configured for each
CAN controller:
Address segment:
The base address (address segment)
is normally adjusted during the installation process. The
selection of the address segment needs to be the same as
that of the hardware configuration.
Port:
Select the port you want to configure.
Baud rate:
The baud rate must be coordinated with the
CAN network. Choose the appropriate one from the list
of baud rates.
Acceptance code:
Specifies the value of the 8 most sig-
nificant bits of the identifier (ID10 ... ID 3)
Acceptance mask:
Specifies the bit positions which are
"relevant" for acceptance filtering.
Note: The acceptance code and acceptance mask are
configured through eight digits (1 digit per bit) using 0
or 1.
Example:
Acc Code = 11111111
Acc Mask =11111111
The shown acceptance filter will accept every received
message.
Interrupt:
Sets the interrupt for each port. Be sure that
this setting matches the IRQ already selected for the
PCM-3860, which accepts values between IRQ3 to
IRQ15, except 8 and 13.
Running mode:
During the normal configuration and
communication process, select Normal Mode. When
the system fails, you can hit <Enter> to reset the CAN
controller. Hit <Enter> again to further execute your
configuration.
Monitor:
Select the port to be monitored from the
<Monitor> pull- down menu. Press F3 to start and stop
the monitoring process.
DataMonitor Utility
Value Definition
0
This bit position will accept only a "relevant" message
1
This bit position will not screen messages.