PCM-3524 User’s Manual
8
2.2.2 PWRDN Power-Down Control (JP5)
When closed, the PCM-3524 is fully operational and enabled. When
opened, the PCM-3524 is configured for minimum power consumption.
D/A converters and clocks are disabled. Previously established set-up
conditions are retained and remain in effect when PWRDN is shorted
again.
2.2.3 RGB_OUT Enable (JP6)
When opened to ON, the PCM-3524 is configured for RGB output, the
COMPOSITE, LUMA, and CHROMA will output R, G, and B respec-
tively. When shorted to OFF, RGB output is disabled.
2.2.4 YUV_OUT Enable (JP8)
When open to ON, the PCM-3524 is configured for YUV output, the
COMPOSITE, LUMA, and CHROMA will output Y, U, and V respec-
tively. When short to OFF, YUV output is disabled.
2.2.5 POWER Selection (JP14)
When short 1-2, the power source from +5V. When short 2-3, the power
source from regulator.