PCL-841 Series User's Manual
Acceptance mask:
Specifies the bit positions which are "relevant",
for acceptance filtering.
Note: The acceptance code and acceptance mask are configured
through eight digits (I digit per bit) using 0 or 1.
Value
Definition
0
This bit position will accept only a’.relevantl message.
1
This bit position will not screen messages.
Example:
Acc Code = 11111111
AccMask= 11111111
The shown acceptance filter will accept every received message.
Interrupt:
Sets the interrupt for each port. Be sure that this
setting matches the IRQ already selected for the
PCL-841, which accepts values between IRQ3 to
IRQ15, except 8 and 13.
Running mode:
During the normal configuration and communica-
tion process, select Normal Mode. When the
system fails, you can hit <Enter> to reset the
CAN controller. Hit <Enter> again to return to
Normal Mode to further execute your configura-
tion.
Monitor
Select the port to be monitored from the <Monitor> pull-down menu.
Press F3 to start and stop the monitoring process.
Monitor screen
The monitored data for a selected port appears in the monitor screen
(see area B in the diagram under Main Menu section.)
If the CAN controller is configured correctly and the transmission has
been successfully completed, every CAN object will be shown inorder
of appearance.
Summary of Contents for PCL-841 Series
Page 2: ...1 Introduction C H A P T E R ...
Page 5: ...4 PCL 841 Series User s Manual ...
Page 6: ...2 Hardware Installation C H A P T E R ...
Page 8: ...Chapter 2 Hardware Installation 7 Jumper and switch locations ...
Page 13: ...12 PCL 841 Series User s Manual ...
Page 14: ...3 Software Programming C H A P T E R ...
Page 22: ...4 DataMonitor Utility C H A P T E R ...
Page 28: ...5 Wiring C H A P T E R ...
Page 31: ...30 PCL 841 Series User s Manual ...