PCI-1720 & 1720U User Manual
34
where
VS: Power supply voltage of current sink.
RL: Load of current sink.
PD: Power dissipation of FET.
When you determine VS and RL, three conditions must be satisfied.
VS > (RL + 249) ( 0.02)
VS £ 50
PD = (VS - (RL + 249) x 0.02) x 0.02 < 0.2
Example 1
If you use the internal power supply VS = +12 V, RL must be less than
351 W (12 / 0.02 - 249 > RL). Select RL = 200 W, PD = 0.0604 < 0.2
OK!
Example 2
If you use the external power supply VS = +40 V, RL must be less than
1.75 kW (40 / 0.02 - 249 > RL).
Select RL = 200 W, PD = 0.62 > 0.2 fail!
Reselect RL = 1 kW, PD = 0.3 > 0.2 fail!