3.2.4 PSU Installation
To install PSU into the PAC-4010 chassis:
1. Align the PSU mechanical edge to the system PSU slot.
2. Carefully slide the FAN module into the system until the connector contacts into the
backplane. Make sure the orange latch is well locked.
To extract PSU from the PAC-4010 chassis:
1. Press the PSU orange latch to unlatch the latch spring. (see
2. Pull the PSU out of chassis.
Figure 3-11: System PSU Installation / Extraction
Caution!
1. DO NOT remove the PSU before unplugging the power cable (power cord).
2. For N+1 redundant system power, only allow ONE PSU to be extracted at
one time.
3. DO NOT leave the slot empty when extracting the PSU, the alternative PSU
MUST be inserted immediately for safety purpose.