MIC-3890 Startup Manual 3
M12 Wago
Power on Sequence
Command name
Command
code
SMBus transaction
type: writing data
SMBus transaction
type: reading data
Number of
data bytes
PMBUS_CMD_READ_VOUT
0x8B
N/A
Read Word
2
PMBUS_CMD_READ_IOUT
0x8C
N/A
Read Word
2
PMBUS_CMD_READ_TEMPE RATURE_1
0x8D
N/A
Read Word
2
Note: 1. SlaveID: 0x6A.
2. Communication data tolerance: VOUT tolerance ±0.2V; IOUT tolerance ≤±0.2A.
3. Communication data unit: VOUT unit is mV; IOUT unit is mA; temperature unit is °C.
4 Temperature takes two bytes. If the high byte is 0, the low byte is positive temperature. If the high byte is not 0,
the low byte data is negative temperature.
5. The PMBus communication function is reserved by BOM option.
Boundary dimension:
length x width×height = 172.06×128.4×40.32±0.3mm (unit: mm).
PMBUS Specification