MIC-3042 User Manual --- Page 3
(MIC-3042B) supporting CT bus application and 500W 2+1 redundant DC CPCI
power supplies.
1.2 Features
• Eight 6U card slots
• Supports front and rear I/O
• Supports H.110 CT application
• 500W 2+1 redundant AC/DC power supply
• Hot-swap compliant backplane
• A hot-swap fan module
• Integrated intelligent management module,MIC-3924L, which can monitor th
e
chassis temperature and fan speed and issue alarm while any abnormal
.
1.3 Specifications
1.3.1 General
• Construction: Aluminum frame and galvanized sheet steel
• 8-slot space (32 TE), including one system slot and seven peripheral slots for
MIC-3042A and six peripheral slots and one media slot for MIC-3042B
• "Hot swappable” platform complies with PICMG 2.1 R 2.0 Hot Swap
Specification
• Dimensions (W x H x D, mounting flanges not included):
4U: 440 x 177 x 320 mm (17.3" x 7" x 12.6")
• Weight: 18 kg (39.7 lb)
• Operating temperature: 0 ~ 45° C
• Storage temperature: -20° C ~ 60° C
• Relative humidity: 10 ~ 95% @ 40° C, non-condensing
• Operating altitude: 0 ~ 3,048 meters (0 ~ 10,000 feet)
• Storage/transit altitude: 0 ~ 12,190 meters (40,000 feet)
• Shock: 10 G (operating); 30 G (storage/transit)
• Random vibration: 1.0 Grms (operating); 2.0 Grms (operating)
1.3.2 Hot-swap Fans
• Air flow: One 193-CFM front fan and one 61.3-CFM rear fan
• Rated fan speed: 3,000 rpm (front fan); 3,400 rpm (rear fran)
Summary of Contents for MIC-3042A
Page 7: ...MIC 3042 User Manual Page 1 1 General Information...
Page 11: ...MIC 3042 User Manual Page 5 Figure 1 2 Appearance of MIC 3042...
Page 12: ...MIC 3042 User Manual Page 6 2 Installation...
Page 17: ...MIC 3042 User Manual Page 11 3 Backplane...
Page 25: ...MIC 3042 User Manual Page 19 Appendix A Pin Assignments of MIB 3042A backplane...
Page 45: ...MIC 3042 User Manual Page 39 Appendix B Pin Assignments of MIB 3042B backplane...
Page 61: ...MIC 3042 User Manual Page 55 Appendix C Ordering Information...