ICR-2441
2.2
Cellular Antennas
Main (ANT) and diversity (DIV) antennas can be connected to the router using the SMA
connectors located on the front panel.
Do not run the router without connected cellular antenna connected to the main antenna
connector as the energy from the transmission is effectively reflected by the open end
and can damage the equipment.
Recommended tightening moment for screwing the antenna to the SMA connector is 0.9 Nm.
The diversity antenna improves the radio capability of the router at low signal strength.
2.3
Ethernet Interfaces
The maximum length of the cables connected to the Ethernet ports is 30 meters to meet
the EMC immunity conditions.
The panel socket of RJ45 is used for Ethernet interface. The pinout of the socket is shown
in Figure
and described in Table
Figure 6: Ethernet Connector Pinout
Pin
Signal mark
Description
1
TXD+
Transmit Data – positive pole
2
TXD-
Transmit Data – negative pole
3
RXD+
Receive Data – positive pole
4
—
—
5
—
—
6
RXD-
Receive Data – negative pole
7
—
—
8
—
—
Table 2: Ethernet Connector Pinout Description
The isolation barrier of the Ethernet ports against the ground is 1500 V.
14