ICR-2412
2.2
Cellular Antennas
Main (ANT) antenna can be connected to the router using the SMA connector located on
the front panel.
Do not run the router without connected cellular antenna connected to the main antenna
connector as the energy from the transmission is effectively reflected by the open end
and can damage the equipment.
Recommended tightening moment for screwing the antenna to the SMA connector is 0.9 Nm.
2.3
Ethernet Interfaces
The panel socket of RJ45 is used for Ethernet interface. The pinout of the socket is shown
in Figure
and described in Table
Figure 6: Ethernet Connector Pinout
Pin
Signal mark
Description
1
TXD+
Transmit Data – positive pole
2
TXD-
Transmit Data – negative pole
3
RXD+
Receive Data – positive pole
4
—
—
5
—
—
6
RXD-
Receive Data – negative pole
7
—
—
8
—
—
Table 2: Ethernet Connector Pinout Description
The isolation barrier of the Ethernet ports against the ground is 1500 V.
14
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: [email protected] — www.lucom.de
www
.lucom.de