background image

User Manual

HIT-W121

Computer

Summary of Contents for HIT-W121

Page 1: ...User Manual HIT W121 Computer...

Page 2: ...nterference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inte...

Page 3: ...se have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application soft...

Page 4: ...ied service personnel 14 If one of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated the equipment c The equipm...

Page 5: ...ndard IEC 60601 1 1 The unit is for exclusive interconnection with IEC 60601 1 certified equipment in the patient environment and IEC 60XXX certified equipment out side of the patient environment If i...

Page 6: ...HIT W121 User Manual vi...

Page 7: ...cations 2 2 1 Mechanical Specifications Terminal 2 2 2 Mechanical Drawing for Rear I O 2 3 External View 2 3 1 Front View 2 3 2 Side Bottom View 2 3 3 Rear View Chapter 3 Software Description 3 1 Wind...

Page 8: ...HIT W121 User Manual viii...

Page 9: ...1 Chapter 1 Introduction This chapter briefly introduces the HIT W121 product f Overview f System Configuration...

Page 10: ...e HIT W121 terminal also serves as an integrated hospital gateway device The HIT W121 equipped with an Intel Atom 1 6GHz Dual core pro cessor 11 6 W Full Flat touch screen onboard isolated Giga LAN po...

Page 11: ......

Page 12: ...HIT W121 User Manual 4...

Page 13: ...2 Chapter 2 Hardware Description This Chapter describes the hard ware features of the HIT W121 f General Specifications f Mechanical Specifications f External View...

Page 14: ...Operating Atmospheric Pressure 700 to 1060 hPa Storage Humidity 10 to 95 No Condensation Storage Atmospheric Pressure 700 to 1060 hPa Transportation Temperature 20 to 60 Transportation Humidity 10 to...

Page 15: ...ions 302 5 W x 220 25 H x 43 00 D mm f Carton Dimensions 500 W x 385 H x 160 f Mounting System VESA 75 75mm standard mounting hole f Net Weight 3 kg VESA Mount 75 75 mm or 100 100 mm SCREWS M4 10 mm C...

Page 16: ...2 2 2 Mechanical Drawing for Rear I O...

Page 17: ...2 3 External View 2 3 1 Front View Front View Terminal 2 3 2 Side Bottom View...

Page 18: ...2 3 3 Rear View Rear View Terminal 9...

Page 19: ......

Page 20: ...3 Chapter 3 Software Description This Chapter describes the soft ware features of the HIT W121 f Windows XP Embedded Software Specifications...

Page 21: ...LC880 Rev 5 10 0 5512 f LAN Marvell Yukon Ethernet Controller Rev 8 61 7 3 f Camera D Max UVC Webcam Rev 6 11 200 4 f Smartcard reader ALCOR micro USB smartcard reader Rev 5 11 9520 7 f Touch Elo Ttou...

Page 22: ...13 HIT W121 User Manual...

Page 23: ...HIT W121 User Manual 14...

Page 24: ...4 Chapter 4 Design Requirements This Chapter describes the design requirements of the HIT W121 f Environmental Specifications f Reliability...

Page 25: ...Less than 40 C 25 C ambient temperature front bezel Safety f CE EMI f FCC class B approved Vibration f 10 18 Hz 1 5 mm peak to peak displacement f 18 500 Hz 1 G acceleration 4 2 Reliability MTBF f 30...

Page 26: ...nded for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the model HIT W121 can help prevent electromagnetic interference by maintain...

Page 27: ...commercial or hospital environment Surge IEC 61000 4 5 r1 kV line s to line s r2 kV line s to earth r1 kV line s to line s r2 kV line s to earth Mains power quality should be that of a typical commerc...

Page 28: ...g symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection fr...

Reviews: