Product Overview
About Power
Redundant power inputs accept 44-57 VDC.
Power consumption is 255 W.
If redundancy is desired, you may connect two separate
power supplies by using the two DC inputs on the terminal
blocks.
About the Ports
The RJ-45 ports auto-negotiate for
10/100/1000Mbps device connections. The
Auto Cross feature allows connections to switches,
workstations, and other equipment without changing
straight through or crossover cabling.
PoE+ Ports
The PoE+ ports on this switch follow Alternative A standards
and support up to 30 Watts of power output per port.
Ports 1 thru 8 support the IEEE802.3at standard and are
classified as PSE power sourcing equipment, which means
they can be used to power (PD) powered devices.
LED Status
LEDS
RJ-45 Ports
SFP Ports
10/100/1000
Copper
POE+ Ports
PoE Reset Function
Power
SFP Ports
POE ON/OFF RESET : To reset/disable PoE, set DIP
switch #1 to ON. (The default setting is OFF.)
POE AUTO RESET : To enable/disable the PoE auto
reset function, set DIP switch #2 to ON. (The default
setting is OFF.)
When Auto RESET is ON, the PoE function will shut
down if both SFP ports lose link, to save power.
The SFP ports support 1000 Mbps Single-mode or
Multi-mode Fiber SFP’s and 1000Mbps copper SFP’s
as long as they are MSA-compliant.
Device Discovery
When the network cables are attached and power
is applied, installation is complete. The switch will
automatically discover network devices, populate
its MAC address table, and pass traffic to the
appropriate ports.
Frame or
Earth Ground
LED
Status Description
FAULT
Green
On
Relay Closed
Green
Off
Relay Open
STA
Green
Flashing System ON
Green
On/Off System down
PWR
(P1, P2)
Green
On
Power Applied
Green
Off
No Power
10/100
/1000
Copper
SPD LED
Green
On
1000 Mbps
Orange
On
100 Mbps
LED Off 10Mbps
10/100
/1000
Copper
LNK LED
Green
On
Link
Green
Flashing Activity
Green
Off
Not connected to network
SFP LED
Green
On
Link
Green
Flashing Activity
Green
Off
Not connected to network
PoE+
Green
On
PWR Supplied
Green
Flashing
Port overload/short circuit
or fail at startup
Green
Off
PWR Not Supplied
1
2
5
3
4