10
EKI-6333AC-A Series User Manual
2.2.2
Wall Mounting
The wall mounting option provides better shock and vibration resistance than the DIN
rail vertical mount.
Before the device can be mounted on a wall, you will need to remove the DIN rail
plate.
1.
Rotate the device to view the rear side and locate the DIN rail mounting plate.
2.
Remove the screws securing the DIN rail mounting plate to the rear side.
3.
Remove the DIN rail mounting plate. Store the DIN rail mounting plate and
provided screws for later use.
4.
Align the wall mounting brackets with the designated location as illustrated in
the following figure. The screw holes on the device and the brackets align if
seated correctnly.
5.
Secure the wall brackets to the device with M3 screws, see the following figure.
Figure 2.8 Installing Wall Mount Plates
Once the wall mounting brackets are secured on the device, mark the screw
hole location on the wall area.
6.
On the installation site, place the device firmly against the wall. Make sure the
device is vertically and horizontally level.
7.
Insert a pencil or pen through the screw holes on the mounting bracket to mark
the location of the screw holes on the wall.
8.
Remove the device from the wall and drill holes over each marked location (4)
on the wall, keeping in mind that the holes must accommodate wall sinks in
addition to the screws.
Note!
When installing, make sure to allow for enough space to properly install
the cabling.