EKI-2728MI 

6G + 2G Fiber Port Industrial 
Unmanaged Gigabit Ethernet 
Switch 

 

User Manual 

Summary of Contents for EKI-2728MI

Page 1: ...EKI 2728MI 6G 2G Fiber Port Industrial Unmanaged Gigabit Ethernet Switch User Manual...

Page 2: ...prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any inf...

Page 3: ...ment materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encount...

Page 4: ...and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harm...

Page 5: ...hing over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient...

Page 6: ...hock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configurat...

Page 7: ...sions units mm 9 Figure 2 1 Front View of EKI 2728MI 9 Figure 2 2 Side View of EKI 2728MI 10 Figure 2 3 Rear View of EKI 2728MI 11 Figure 2 4 Top View of EKI 2728MI 12 2 3 Mounting 13 2 3 1 Wall mount...

Page 8: ...EKI 2728MI_Manual_ed1 doc viii...

Page 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER...

Page 10: ...mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 4 Advanced Protection EKI 2728MI supports up to 3 000 VDC surge protection for power line and also support...

Page 11: ...iation Provides surge EFT protection 3 000 VDC for power line Supports 4 000 VDC Ethernet ESD protection Provides Slim size DIN rail with IP30 metal mechanism Supports Redundant 12 48 VDC 24 VAC power...

Page 12: ...Active Speed Power Power Consumption Max 9 3W Power Input 2 x Unregulated 12 48 VDC and 24 VAC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 59 6 x 105 x 152 mm Enclosure IP30 Metal shell wi...

Page 13: ...Certifications Safety UL508 Class 1 Division 2 EMC FCC Class A EU EN61000 6 2 4 EN61000 3 3 3 EN61000 4 2 3 4 5 6 8 11 12 Freefall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 5 Chapter1...

Page 14: ...l Communication CD ROM and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2728MI Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution Att...

Page 15: ...7 Chapter2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER...

Page 16: ...PWR1 Green Off Power input 1 is inactive On Power input 2 is active PWR2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive P Fail Red Off Power input 1 and 2 are both active or no...

Page 17: ...2 2 Dimensions units mm Figure 2 1 Front View of EKI 2728MI 9 Chapter2...

Page 18: ...Figure 2 2 Side View of EKI 2728MI EKI 2728MI_Manual_ed1 doc 10...

Page 19: ...Figure 2 3 Rear View of EKI 2728MI 11 Chapter2...

Page 20: ...The power relay terminal block is located on the top Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2728MI EKI 2728MI_Manual_ed1 doc 12...

Page 21: ...g the included mounting kit Then hang on the EKI 2728MI to the nails on the wall First use the screws included in the package to combine the EKI 2728MI and metal mounting kit And then you can install...

Page 22: ...crewed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2728MI to the DIN r...

Page 23: ...Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 15 Chapter2...

Page 24: ...pports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X station port on the switch to any device such as a switch bridge or router 2 5 Power Connection The EKI...

Page 25: ...17 Chapter2 Troubleshooting CHAPTER...

Page 26: ...ections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which de...

Page 27: ...19 Chapter2 Pin Assignment Wiring APPENDIX...

Page 28: ...ppendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A EKI 2728MI_Manual_ed1 doc 20...