Safety Instructions 

 
1.  Read these safety instructions carefully. 
2.  Keep this User's Manual for later reference. 
3.  Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not 

use liquid or spray detergents for cleaning. 

4.  For plug-in equipment, the power outlet socket must be located near the equipment and 

must be easily accessible. 

5.  Keep this equipment away from humidity. 
6.  Put this equipment on a reliable surface during installation. Dropping it or letting it fall may 

cause damage. 

7.  The openings on the enclosure are for air convection. Protect the equipment from 

overheating. DO NOT COVER THE OPENINGS. 

8.  Make sure the voltage of the power source is correct before connecting the equipment to 

the power outlet. 

9.  Position the power cord so that people cannot step on it. Do not place anything over the 

power cord. 

10.  All cautions and warnings on the equipment should be noted. 
11. If the equipment is not used for a long time, disconnect it from the power source to avoid 

damage by transient overvoltage. 

12.  Never pour any liquid into an opening. This may cause fire or electrical shock. 
13. Never open the equipment. For safety reasons, the equipment should be opened only by 

qualified service personnel. 

14.  If one of the following situations arises, get the equipment checked by service personnel: 

a.  The power cord or plug is damaged. 
b.  Liquid has penetrated into the equipment. 
c.  The equipment has been exposed to moisture. 
d.  The equipment does not work well, or you cannot get it to work according to the user's 

manual. 

e.  The equipment has been dropped and damaged. 

f.  The equipment has obvious signs of breakage. 

 
15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE 

TEMPERATURE MAY GO BELOW -40

 (-40

) OR ABOVE 85

 (185

). THIS 

COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A 
CONTROLLED ENVIRONMENT. 

Summary of Contents for EKI-2525PA

Page 1: ...EKI 2525PA 5 port Industrial Unmanaged Ethernet Switch with 4 port PoE User Manual...

Page 2: ...or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility...

Page 3: ...lacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enc...

Page 4: ...iate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential...

Page 5: ...ything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transien...

Page 6: ...mage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power...

Page 7: ...mensions units mm 9 Figure 2 1 Front View of EKI 2525PA 9 Figure 2 2 Side View of EKI 2525PA 10 Figure 2 3 Rear View of EKI 2525PA 11 Figure 2 4 Top View of EKI 2525PA 12 2 3 Mounting 13 2 3 1 Wall mo...

Page 8: ...EKI 2525PA User Manual viii...

Page 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER...

Page 10: ...ion costs in many cases 1 1 3 Dual Power Input EKI 2525PA redundant power input design is with power reserve protection to prevent the switch device broken by wrong power wiring When one of power inpu...

Page 11: ...w control Supports store and forward transmission Supports auto negotiation Supports MDI MDI X auto crossover Provides surge protection EFT 3 000 VDC for power line Supports 4 000 VDC ESD protection f...

Page 12: ...Duplex Collision Power Power Consumption 62 5 Watts 48 VDC 67 Watts 24 VDC Full load with PoE Power Input 2 x Unregulated 24 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 48 6 x 140 x...

Page 13: ...5 Chapter1 Certifications Safety UL cUL 508 EMC U S A FCC Part 15 CISPR 22 EU EN55011 IEC61000 4 2 3 4 5 6 8 EN61000 6 1 3 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6...

Page 14: ...cation CD ROM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2525PA Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precautio...

Page 15: ...7 Chapter2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER...

Page 16: ...Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive P Fail Red Off Power input 1 and 2 are both active or no power i...

Page 17: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 2525PA...

Page 18: ...EKI 2525PA User Manual 10 Figure 2 2 Side View of EKI 2525PA...

Page 19: ...11 Chapter2 Figure 2 3 Rear View of EKI 2525PA...

Page 20: ...EKI 2525PA User Manual 12 Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2525PA...

Page 21: ...nted by using the included mounting kit Then hang on the EKI 2525PA to the nails on the wall First use the screws included in the package to combine the EKI 2525PA and metal mounting kit And then you...

Page 22: ...teps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang t...

Page 23: ...15 Chapter2 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2...

Page 24: ...ther hub or switch either MDI X or uplink MDI port The EKI 2525PA supports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X station port on the switch to any de...

Page 25: ...17 Chapter2 Troubleshooting CHAPTER...

Page 26: ...length of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user...

Page 27: ...19 Chapter2 Pin Assignment Wiring APPENDIX...

Page 28: ...EKI 2525PA User Manual 20 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A...

Reviews: