background image

 

EKI-2525 & 2528 User Manual

                                             

1.3  Specification 

 

 

Communications 

 

 

Compatibility

 

IEEE 802.3, 802.3u, 802.3x 

LAN

 

10/100Base-TX 

Transmission Distance

 

Up to 100 m 

Transmission Speed

 

Up to 100 Mbps 

 

 

 

 

Interface 

 

 

Connectors

 

5 x RJ-45 (EKI-2525) 

 

8 x RJ-45 (EKI-2528) 

 

6-pin removable screw terminal (power) 

LED Indicators

 

Unit: P1, P2, P-Fail 

 

TX port: Link/Active, Duplex/Collision 

 

 

 

 

Power 

 

 

Current Overload Protection

 

0.9A@12V

DC

  (25 ) 

Power Consumption 

2.93 W (EKI-2525) 

 

4.71 W (EKI-2528) 

Power Input

 

2 x Unreg12 ~ 48 V

DC

 

Fault Output

 

1 Relay Output 

 

 

 

 

Mechanism 

 

 

Dimensions (WxHxD)

 

37 x 140 x 95 

Enclosure

 

IP30, Metal shell with solid mounting

 

kits 

Mounting

 

DIN-rail, Wall 

 

 

 

 

Protection 

 

 

ESD (Ethernet)

 

4000 V

DC

 

Surge (EFT for power)

 

3000 V

DC

 

Power Reverse

 

Yes 

 

 

 

 

Environment 

 

 

Operating Temperature

 

-10 ~ 60

 

Operating Humidity

 

5% ~ 95% (non-condensing) 

Storage Temperature

 

-40 ~ 85

 

 

 

 

 

Summary of Contents for EKI-2525

Page 1: ...EKI 2525 5 port 10 100Base TX Industrial Unmanaged Ethernet Switch EKI 2528 8 port 10 100Base TX Industrial Unmanaged Ethernet Switch User Manual ...

Page 2: ...orm or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS D...

Page 3: ...placement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer an...

Page 4: ...adiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web si...

Page 5: ...nything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service ...

Page 6: ...damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components ...

Page 7: ...mm 9 Figure 2 1 Front View of EKI 2525 2528 9 Figure 2 2 Side View of EKI 2525 2528 10 Figure 2 3 Rear View of EKI 2525 2528 11 Figure 2 4 Top View of EKI 2525 2528 12 2 3 Mounting 13 2 3 1 Wall mounting 13 Figure 2 5 Combine the Metal Mounting Kit 13 2 3 2 DIN rail Mounting 14 Figure 2 6 Installation to DIN rail Step 1 14 Figure 2 7 Installation to DIN rail Step 2 15 2 4 Network Connection 16 2 5...

Page 8: ...EKI 2525 2528 User Manual viii ...

Page 9: ...1 Chapter1 Overview Sections include Introduction Features Specifications Packing List Safety Precaution CHAPTER ...

Page 10: ... Flexible Mounting EKI 2525 2528 is extremely compact 37 x 140 x 95 mm and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 4 Advanced Protection EKI 2525 2528 supports up to 3 000 VDC surge protection for power line and also supports 4000V ESD for Ethernet ports With these 2 strong protections it can secure equipment against unregulated voltage a...

Page 11: ... duplex flow control Supports store and forward transmission Supports auto negotiation Supports MDI MDI X auto crossover Provides surge protection EFT 3 000 VDC for power line Supports 4 000 VDC ESD protection for Ethernet Supports 12 48 VDC power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperature from 10 60 ...

Page 12: ... P Fail TX port Link Active Duplex Collision Power Current Overload Protection 0 9A 12VDC 25 Power Consumption 2 93 W EKI 2525 4 71 W EKI 2528 Power Input 2 x Unregulated 12 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 37 x 140 x 95 Enclosure IP30 Metal shell with solid mounting kits Mounting DIN rail Wall Protection ESD Ethernet 4000 VDC Surge EFT for power 3000 VDC Power Reverse...

Page 13: ... UL 60950 1 CAN CSA C22 2 No 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 12 EN61000 6 2 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 ...

Page 14: ...mmunication CD ROM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2525 2528 Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Page 15: ...7 Chapter2 Installation Sections include LED Indicators Dimensions Mounting Network Connection Power Connection CHAPTER ...

Page 16: ...2525 2528 LED Definition LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive P Fail Red Off Power input 1 and 2 are both active or no power input On Connected to network Flashing Networking is active Link Active 1 5 or 1 8 Green Off Not connected to network On Eth...

Page 17: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 2525 2528 ...

Page 18: ...EKI 2525 2528 User Manual 10 Figure 2 2 Side View of EKI 2525 2528 ...

Page 19: ...11 Chapter2 Figure 2 3 Rear View of EKI 2525 2528 ...

Page 20: ...EKI 2525 2528 User Manual 12 Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2525 2528 ...

Page 21: ...l mounted by using the included mounting kit Then hang on the EKI 2525 2528 to the nails on the wall First use the screws included in the package to combine the EKI 2525 2528 and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit ...

Page 22: ... steps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2525 2528 to the DIN rail with angle of inclination See figure 2 6 Figure 2 6 Installation to DIN rail Step 1 ...

Page 23: ...15 Chapter2 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 ...

Page 24: ... 2528 MDI X to another hub or switch either MDI X or uplink MDI port The EKI 2525 2528 supports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X station port on the switch to any device such as a switch bridge or router 2 5 Power Connection The EKI 2525 2528 supports dual 12 48 VDC power inputs and power fail relay output Figure 2 8 Pin Assignment of the Pow...

Page 25: ...17 Chapter2 Troubleshooting CHAPTER ...

Page 26: ... the length of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is plugged in user may have a problem with power cord...

Page 27: ...19 Chapter2 Pin Assignment Wiring APPENDIX ...

Page 28: ...EKI 2525 2528 User Manual 20 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A ...

Reviews: